AR-M550/M620  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 30
Main 
code
Sub 
code
Title
Fusing section high temperature 
trouble
H3
00/
HL1
Phenomenon
Display
Lamp
Message
01/
HL2
Details
Fusing section high 
temperature trouble
The fusing temperature 
exceeds 241.5°C. (An 
input voltage of 0.35V or 
less is detected.)
When fusing temperature 
control is started and a 
temperature of 242°C is 
detected 3 times 
continuously in sampling 
of 100 (150) msec 
interval. (Except for 
Japan)
02/
HL3
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Thermistor trouble
Control PWB trouble
Improper connection of 
the fusing section 
connector
AC power trouble
Remedy
Use SIM 5-2 to check 
flashing of the heater 
lamp.
When the lamp flashes 
normally.
• Check the thermistor 
and the harness.
• Check the thermistor 
input circuit on the 
control PWB.
When the lamp keeps 
ON.
• Check the AC PWB 
and the lamp control 
circuit on the control 
PWB.
Use SIM 14 to cancel the 
trouble
Note 
Main 
code
Sub 
code
Title
Fusing section low temperature 
trouble
H4
00/
HL1
Phenomenon
Display
Lamp
Message
01/
HL2
Details
Fusing section low 
temperature trouble
The set temperature is 
not reached within the 
specified time (normally 4 
min) after turning on the 
power relay.
The heater lamp does not 
turn off in 4 min after 
starting warming up.
After completion of 
warming up, a 
temperature of 80°C is 
detected 5 times 
continuously in sampling 
of 100 (150) msec 
interval. (Except for 
Japan)
02/
HL3
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Thermistor trouble
Heater lamp trouble
Control PWB trouble
Thermostat trouble
AC power trouble
Interlock switch
Remedy
Use SIM 5-2 to check 
flashing of the heater 
lamp.
When the lamp flashes 
normally.
• Check the thermistor 
and the harness.
• Check the thermistor 
input circuit on the 
control PWB.
When the lamp does not 
turn on.
• Check for 
disconnection of the 
heater lamp or the 
thermostat.
• Check the interlock 
switch.
• Check the AC PWB 
and the lamp control 
circuit on the control 
PWB.
Use SIM 14 to cancel the 
trouble
Note 