Read Sharp AR-M550 (serv.man142) Technical Bulletin online
CC001
Sharp Electronics (UK) Ltd., Technical Services Group
5.Procedure
1
Remove the fuser unit from the machine.
2
Take off the fuser pressure using the two grey coloured screws (pressure screws).
Then remove the two screws, which locks the upper fuser section to the lower.
(lock screws).
Then remove the two screws, which locks the upper fuser section to the lower.
(lock screws).
3
Remove the lower roller and the cleaner blade and the silver paper guide plate.
Pressure Screws
Lock Screw
Lock Screw