AR-M550 (serv.man14). (7) Settings and adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 6

Read Sharp AR-M550 (serv.man14) Service Manual online

AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 6
4) Go through the modes specified in Simulation 8-18.
5) Select the number that corresponds to the adjustment item (CRHV
PLUS / CRHV MINUS) using the numeric keypad.  
6) Press the Start key
7) Press the Start key to have the voltage output for 30 seconds. 
The operation can be stopped with the CUSTOM SETTINGS key. 
If the output voltage is not within the requirement, do the following
steps. 
8) Enter the adjustment value using the numeric keypad. 
9) Press the Start key.
(The adjustment value is put into memory, and the corresponding
voltage is output for 30 seconds.) 
Repeat steps 8 to 9 until the output requirement is satisfied.
This adjustment is needed in the following situations: 
• The developing unit has been disassembled. 
• The print density is low. 
• The toner is excessively dispersed.
1) Remove the developing unit of the machine.
2) Remove the developing unit cover and blade cover.
3) Loosen the DV doctor fixing screws.
4) Manually turn the DV roller to align the marking on the DV roller
surface with the DV doctor position.
5) Insert a 0.525mm clearance gauge in between the DV roller and
DV doctor so that the gauge is positioned at a distance of 40 mm to
70 mm from the DV doctor end face.
6) Tighten the DV doctor fixing screws while pressing the DV doctor
in the arrow direction.
(This should be done for both front and rear frames.)
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
ADJ 2
Adjusting the developing unit
ADJ 2A
Adjust the developing doctor gap
SIMULATION 8-18
1
TRANSFER CLEANING ROLLER SETTING. SELECT 1-2, AND 
PRESS START.
1.CRHV PLUS    
50
 
2.CRHV MINUS   
50
SIMULATION 8-18
TRANSFER CLEANING ROLLER SETTING. INPUT VALUE, AND 
PRESS START.
1.CRHV PLUS (0-250) 
200
SIMULATION 8-18
TRANSFER CLEANING ROLLER SETTING. EXECUTING···.
1.CRHV PLUS(0-250)
200
Page of 44