AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 17
6) Select the number that corresponds to the adjustment item CCD
(MAIN) using the numeric keypad. 
This adjustment item is intended to adjust the image magnification
in the main scanning direction in original table mode (CCD). 
7) Press the Start key
8) Adjust the image magnification factor by entering an appropriate
value through the numeric keypad. 
9) Press the P or Start key
Pressing the Start key starts copy operation as well as applying the
adjustment value.
Repeat steps 2 to 9 until the image magnification factor is satisfactory.
This adjustment is needed in the following situations: 
• The CCD unit has been removed from the machine. 
• The CCD unit has been replaced. 
• Images are not correctly magnified in the sub-scanning direction. 
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scan control PWB has been replaced.
• The EEPROM on the scan control PWB has been replaced.
• U2 trouble has occurred. 
1) Place a scale on the original table as illustrated below.
2) Make a normal copy on A4 paper.
3) Measure the lengths of the copied image of the scale and the
actual scale.
4) Determine the image magnification factor using the following for-
mula:
Image magnification factor (%) = Copy dimension/original dimen-
sion x 100
Example: Compare the copy and original dimensions by aligning
the scale's 10 mm position with the copied image's 10 mm position.
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100±0.8%), no
adjustment is required; otherwise, do the following steps.
Select 2, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
50
1
2
Select other than 0 - 2, 
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key. 
Press [CUSTOM SETTINGS] key, 
or terminate copying.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
 5.SPF(SUB) 
50
6.CIS(MAIN) 
50
 7.SPF(MAIN) 
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT   6.LCC
   (ABOVE+10: DUPLEX MODE)
Select 1, and 
press [START] key. 
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
  INPUT 25-400(%)
ADJ 6B
Adjust the image magnification in the 
sub-scanning direction in original table 
mode
10 20 30 40 50 60 70 80 90 100110120130140
10
20
90
100
110
10
20
90
100
110
100mm scale
(Original)
Copy image
(1mm (1%)
shorter than 
the original)
0.8mm
Page of 44