AR-M550 (serv.man10). (5) External view and internal structure - Sharp Copying Equipment Service Manual (repair manual). Page 16

Read Sharp AR-M550 (serv.man10) Service Manual online

AR-M550/M620  EXTERNAL VIEW AND INTERNAL STRUCTURE  5 - 15
F. Fan motor
Code
Signal 
name
Name
Type
Function/Operation
Active 
condition
 MODEL
 NOTE
CFM-DC1
CFM-DC1
Power cooling fan motor
DC brushless 
motor
Cools the DC power unit.
CFM-DC2
CFM-DC2
Power cooling fan motor
DC brushless 
motor
Cools the DC power unit.
CFM-DV
CFM-DV
Developing section cooling 
fan motor
DC brushless 
motor
Cools the developing 
section.
PWM control
CFM-HDD
CFM-HDD
HDD cooling fan motor
DC brushless 
motor
Cools the HDD.
PWM control
CFM-ICU
CFM-ICU
Controller cooling fan motor
DC brushless 
motor
Cools the controller.
PWM control
CFM-R1
CFM-R1
Process cooling fan motor 1 
(LSU/process section)
DC brushless 
motor
Cools the LSU/ process 
section.
PWM control
CFM-R2
CFM-R2
Process cooling fan motor 2 
(LSU/process section)
DC brushless 
motor
Cools the LSU/ process 
section.
PWM control
CFM-R3
CFM-R3
Process cooling fan motor 3 
(LSU/process section)
DC brushless 
motor
Cools the LSU/ process 
section.
PWM control
CFM-U1
CFM-U1
Fusing section cooling fan 
motor 1 (Paper exit/duplex 
(ADU) section) (Top surface)
DC brushless 
motor
Exhaust heat from the 
fusing section.
PWM control
CFM-U2
CFM-U2
Fusing section cooling fan 
motor 2 (Paper exit/duplex 
(ADU) section) (Paper exit 
rear side)
DC brushless 
motor
Exhaust heat from the 
fusing section.
PWM control
CFM-U3
CFM-U3
Fusing section cooling fan 
motor 3 (Paper exit/duplex 
(ADU) section)(Top surface)
DC brushless 
motor
Exhaust heat from the 
fusing section.
PWM control
CFM-U4
CFM-U4
Fusing section cooling fan 
motor 4 (Paper exit/duplex 
(ADU) section) (Paper exit 
rear side)(Paper cooling fan 
motor)
DC brushless 
motor
Exhaust heat from the 
fusing section.
Cools paper which is 
discharged to the inner 
tray.
PWM control
SPFFAN
SPFFAN
SPF fan motor
DC brushless 
motor
Cools the motor and the 
clutch in the SPF.
PWM control
VFM-BKL
VFM-BKL
Process paper exit fan motor 
4
DC brushless 
motor
Exhaust ozone and heat 
from the process section.
PWM control
CFM-HDD
CFM-DV
SPFFAN
VFM-BKU
CFM-U2
CFM-U4
VFM-BKR
CFM-ICU
CFM-DC1
CFM-DC2
VFM-BKL
CFM-R1
CFM-R2
CFM-R3
CFM-U3
VFM-EX1
VFM-EX2
VFM-EX3
CFM-U1
Page of 25
Display