AR-M351U, AR-M451U (serv.man17). Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 63

Read Sharp AR-M351U / AR-M451U (serv.man17) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 63
Operation/Procedure
1) Set the SPF paper feed guide to the max. position.
2) Select "MAX. POSITION" with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CSUTOM SETTING] key.
5) Set the SPF paper feed guide to A4R size position.
6) Select POSITION 1 with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CSUTOM SETTING] key.
9) Set the SPF paper feed guide to A5R size position.
10)  Select POSITION 2 with 10-key.
11)  Press [START] key.
The A5R width detection level is recognized.
12) Press [CSUTOM SETTING] key.
13) Set the SPF paper feed guide to the min. position.
14) Select "MIN. POSITION" with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, ERROR is
displayed. When completed normally, COMPLETE is displayed.
Operation/Procedure
1) Enter the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10key.
4) Press [START] key.
Select 0, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
53
53-6
Purpose
Adjustment
Function
(Purpose)
Used to adjust the DSPF width detection level.
Section
Item
Operation
60
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0.TRAY SELECT 
1
  1.PRINT START
2.TRAY1 
60
      3.TRAY2 
50
  4.DESK 
50
5.BPT   
55
      6.ADU   
50
 
7.SPF(HIGH) 
60
  8.SPF(LOW) 
75
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
2.TRAY1
Select 1, 
and press
 [START] key.
Select other than 0 - 1, and 
press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key, 
or terminate copying.
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT
   (ABOVE+10: DUPLEX MODE)
Select 4, and press [START] key.
Press [CUSTOM SETTINGS] key.
53-7
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function
(Purpose)
Used to enter the SPF width detection adjustment 
value.
Section
DSPF
Item
Operation
Item
Set range Default
1 MAX. POSITION Max. width
0 - 1023
66
2 POSITION 1
Adjustment position 1
456
3 POSITION 2
Adjustment position 2
713
4 MIN. POSITION Min. width
791
Press [START] key.
Press [CUSTOM SETTINGS] key.
1
Select 2, and press [START] key.
Select 3, and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or “ERROR”)
Select 1, and 
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or “ERROR”)
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION:   
66
2.POSITION 1  :  
456
3.POSITION 2  :  
713
4.MIN.POSITION:  
791
66
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1.MAX.POSITION
Page of 88