DR26022002-1
Sharp Electronics (UK) Ltd., Technical Services Group
                                      
7. 
Remove the 4 screws securing the hinge to the paper feed unit.
                                    
8. 
Lower the paper feed unit from the cabinet to allow enough clearance behind the
SPF paper guide to remove it from the paper feed unit.
9. 
Remove the existing PS support roller by removing the 2 screws and plate springs
securing the PS support roller shaft to the paper guide and replace the PS support
roller with the modified version.
                             
10. 
Reassemble in the reverse order and check skew, realigning as necessary.
Replacement of the PS support roller is all that should be necessary to correct the
skew. However, in extreme circumstances it may be necessary to also replace the
SPF paper guide with a modified version. If this becomes necessary it will be
necessary to attach a mylar sheet to the paper guide.
PS REAR MYLAR  - P/No. PSHEP4915FCZZ – Price Rank AE.