AR-M35, AR-M450 (serv.man73). Flash ROM version upgrade procedure (Revised) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp AR-M35 / AR-M450 (serv.man73) Technical Bulletin online

DRAug2001-1 (Revision 3)
Sharp Electronics (UK) Ltd., Technical Services Group
TIGER PARALLEL UPDATE
PROCEDURE Windows 95/98
1 Set Tiger Control PWB jumpers as indicated on the following page.
2 1) Turn on main switch.
2) "Boot Program Init
      Please Wait"
(displayed)
3) "Version Check Conf : ××××"
(displayed)
4) Press menu key twice.
5) "Firm Update
      From Parallel"
(displayed)
6) Press OK button twice.
7) "Firm Update
      Waiting Data"
(displayed)
8) Drag the .sfu file
    to fcopy exe.
See Fig 1.below
9) Display changes to "Firm Update Conf Writing Data"
(displayed)
10) Display changes to "Firm Update Result : OK"
      (Takes some time)
(displayed)
11) Press OK button once.
12) Turn off main switch.
3 Reset the Tiger Control PWB jumpers to
default settings
Firmware is updated.
CAUTION :
Don't turn off the main switch until Display changes to "Firm Update Result : OK"
Fig. 1.
 Using Windows Explorer - Left Mouse Click on .SFU file and drag onto fcopy.exe. Release mouse button.
Dos box will open and file transfer will commence via parallel port .
Page of 3
Display