Read Sharp AR-M35 / AR-M450 (serv.man73) Technical Bulletin online
DRAug2001-1 (Revision 3)
Sharp Electronics (UK) Ltd., Technical Services Group
TIGER PARALLEL UPDATE
PROCEDURE Windows 95/98
PROCEDURE Windows 95/98
1 Set Tiger Control PWB jumpers as indicated on the following page.
2 1) Turn on main switch.
2) "Boot Program Init
Please Wait"
Please Wait"
(displayed)
3) "Version Check Conf : ××××"
(displayed)
4) Press menu key twice.
5) "Firm Update
From Parallel"
From Parallel"
(displayed)
6) Press OK button twice.
7) "Firm Update
Waiting Data"
Waiting Data"
(displayed)
8) Drag the .sfu file
to fcopy exe.
to fcopy exe.
See Fig 1.below
9) Display changes to "Firm Update Conf Writing Data"
(displayed)
10) Display changes to "Firm Update Result : OK"
(Takes some time)
(Takes some time)
(displayed)
11) Press OK button once.
12) Turn off main switch.
3 Reset the Tiger Control PWB jumpers to
default settings
Firmware is updated.
Firmware is updated.
CAUTION :
Don't turn off the main switch until Display changes to "Firm Update Result : OK"
Fig. 1.
Using Windows Explorer - Left Mouse Click on .SFU file and drag onto fcopy.exe. Release mouse button.
Dos box will open and file transfer will commence via parallel port .
Click on the first or last page to see other AR-M35 / AR-M450 (serv.man73) service manuals if exist.