Read Sharp AR-M35 / AR-M450 (serv.man7) Handy Guide online
Test Simulation
Version 2.0
Issue 01/02
19
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
AR-P350 Diagnostic Mode Notes.
Diagnostic Mode Entry
When the scanner unit is not installed, the machine can be checked and tested with the following diagnostics mode.
To cancel diagnostic mode, turn the power off.
Hold
the
MENU
and OK keys down whilst turning on the main power switch.
Machine Data Print
1. In diagnostic mode press MENU 12 times to display Test print 00
2.
2.
Press OK. The machine will enter warm up mode with no indication on the display.
3. Multi setting.
Use
tuto select the number of copies required.
4. MENU
. Print pattern. Use
tuto select the test pattern required.
PP1
Centre line for centre alignment checks
PP2
Half tone full page coverage for image loss checks.
PP65 Pattern test for laser focus checks.
PP66 Laser write pattern
PP67 Laser write pattern
PP68 Laser write pattern
PP70 Alignment scale test chart
PP71 All square pattern
PP72 Diagonal
PP66 Laser write pattern
PP67 Laser write pattern
PP68 Laser write pattern
PP70 Alignment scale test chart
PP71 All square pattern
PP72 Diagonal
pattern
PP73 Diagonal
pattern
PP74 Diagonal
pattern
PP75 ID patch print
PP87 Sharp test sheet B
PP88 Ageing chart 6% toned area
PP89 Ageing chart 5% toned area
PP98 Machine data print out (SIM 22 – 06)
PP87 Sharp test sheet B
PP88 Ageing chart 6% toned area
PP89 Ageing chart 5% toned area
PP98 Machine data print out (SIM 22 – 06)
5. MENU. Cassette. Use
tuto select the paper source. (Note BPT = MFT)
6. MENU. Duplex. Use
tuto select Duplex mode.
7. MENU. Output. Use
tuto select the type of output dependent on the options fitted .
8. Press
OK
for test prints.
Note: If the scanner unit is installed this mode does not work.
Notes
A)
The OK key can be pressed at any time for the machine to produce a test print. However, if OK is pressed
and the data light remains flashing and no print is produced check the type of output selected. It may be
that the optional unit required for that type of output is not installed. For example BIN # selected with no
AR-MS1 installed.
that the optional unit required for that type of output is not installed. For example BIN # selected with no
AR-MS1 installed.
B)
Pressing the Information key will return to the previous Menu item.
For example, return from Output to Duplex press INFORMATION.
C) Pressing
BACK/C
to the main menu item.
For example, in Output press BACK/C returns to Test Print 0