AR-M35, AR-M450 (serv.man7). ARM350 450 ARP350 450 Handy Guide (NEW) - Sharp Copying Equipment Handy Guide. Page 19

Read Sharp AR-M35 / AR-M450 (serv.man7) Handy Guide online

 
Test Simulation 
 
 
Version 2.0 
Issue 01/02 
 
19 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS SUPPORT 
TECHNICAL SERVICES GROUP
 
 
AR-P350 Diagnostic Mode Notes. 
Diagnostic Mode Entry
  
 
When the scanner unit is not installed, the machine can be checked and tested with the following diagnostics mode. 
To cancel diagnostic mode, turn the power off. 
 
 
 Hold 
the 
MENU
 and OK keys down whilst turning on the main power switch
 
 
Machine Data Print 
 
 
1.  In diagnostic mode press MENU 12 times to display Test print 00 
2. 
Press OK. The machine will enter warm up mode with no indication on the display. 
3.  Multi setting. 
Use 
tuto select the number of copies required. 
4. MENU
Print pattern. Use 
tuto select the test pattern required. 
PP1 
Centre line for centre alignment checks 
PP2 
Half tone full page coverage for image loss checks. 
PP65  Pattern test for laser focus checks. 
PP66  Laser write pattern 
PP67  Laser write pattern 
PP68  Laser write pattern 
PP70  Alignment scale test chart 
PP71  All square pattern 
PP72 Diagonal 
pattern 
PP73 Diagonal 
pattern 
PP74 Diagonal 
pattern 
PP75  ID patch print 
PP87  Sharp test sheet B 
PP88  Ageing chart 6% toned area 
PP89   Ageing chart 5% toned area 
PP98  Machine data print out (SIM 22 – 06) 
5.  MENUCassette. Use 
tuto select the paper source. (Note BPT = MFT) 
6.  MENUDuplex. Use 
tuto select Duplex mode. 
7.  MENUOutput. Use 
tuto select the type of output dependent on the options fitted  . 
8. Press 
OK 
for test prints. 
 
 
 
 
Note: If the scanner unit is installed this mode does not work. 
 
Notes 
A) 
The OK key can be pressed at any time for the machine to produce a test print. However, if OK is pressed 
and the data light remains flashing and no print is produced check the type of output selected. It may be 
that the optional unit required for that type of output is not installed. For example BIN # selected with no 
AR-MS1 installed. 
B) 
  Pressing the Information key will return to the previous Menu item. 
For example, return from Output to Duplex press INFORMATION. 
 
C) Pressing 
BACK/C 
to the main menu item. 
For example, in Output press BACK/C returns to Test Print 0 
 