AR-M256/M257/M258/M316/M317/M318/5625/5631  TROUBLE CODE LIST 9 - 11
L4
11
Content
Shifter motor trouble
Details
The shifter home position detection signal 
is not detected when the shifter is 
operating.
Cause
Shifter motor trouble or harnes connection 
trouble and disconnection.
Shifter home position sensor trouble.
Check 
and 
remedy
Check the shifter motor operation with SIM 
3-11.
Check connection of the shifter motor 
harness/connector.
Replace the shifter motor.
Replace the MCU PWB.
L6
10
Content
Polygon motor lock trouble
Details
The polygon motor does not rotate.
The motor lock signal is detected for 6sec 
or more after the polygon motor rotates.
The motor lock signal is detected for 1sec 
during rotation of the polygon motor.
Cause
Polygon motor unit failure
Polygon motor connection, harness trouble 
or disconnection
MCU PWB failure
Check 
and 
remedy
Check the polygon motor operation with 
SIM 61-1.
Check the connectors and the harness of 
polygon motor
Replace the polygon motor.
Replace the MCU PWB.
L8
10
Content
Power abnormality detection trouble
Details
The power status monitoring signal keeps 
power OFF state after passing the 
specified time (2sec).
Cause
Circuit around the power status monitoring 
signal (PSSTS) failure.
Check 
and 
remedy
Check whether power status monitoring 
signal (PSSTS) on MCU PWB is OPEN or 
not.
Replace MCU PWB.
U1
01
Content
FAX battery error
Details
The SRAM backup battery voltage on FAX 
control PWB falls.
Cause
The SRAM backup battery voltage on FAX 
control PWB falls.
Check 
and 
remedy
Check voltage of the SRAM back up 
battery.
Replace the battery.
02
Content
PANEL LOW battery error
Details
The voltage of the panel clock function 
battery falls.
Cause
The voltage of the panel clock function 
battery falls.
Check 
and 
remedy
Check voltage of panel clock function 
battery.
Replace the battery.
Trouble 
code
Details of trouble
Main 
code
Sub 
code
U2
04
Content
EEPROM communication error
Details
EEPROM communication error
Cause
EEPROM defect.
ICU PWB EEPROM access circuit failure.
Check 
and 
remedy
Check that the EEPROM is properly set.
Clear trouble with SIM 16.
Replace the MCU PWB.
20
Content
Machine speed code data error
Details
The machine boot speed information is not 
identical to the model code speed 
information
Cause
EEPROM defect.
SIM operation error.
Check 
and 
remedy
Check for matching of the machine and 
model information setting in SIM26-57.
40
Content
CRUM chip communication error
Details
Error in MCU-CRUM chip communication
Cause
CRUM chip failure.
Developing unit contact trouble.
MCU PWB failure.
Check 
and 
remedy
Replace the CRUM chip.
Check installation of the developing unit.
Clear the trouble with SIM 16.
Replace the MCU PWB.
Remarks
CRUM communication error
U7
00
Content
RIC communication trouble
Details
Error in communication with RIC.
Error in communication test after turning 
on the power or canceling SIM.
Cause
Connector harness contact trouble or 
disconnection.
RIC control PWB trouble.
MCU PWB failure.
Malfunction by noises.
Check 
and 
remedy
Check the communication cable, 
connectors from the RIC box to the main 
body.
U9
00
Content
Operation control PWB communication 
trouble
Details
Communication trouble between MCU and 
the operation control PWB
Cause
Operation control PWB connector 
disconnection
Harness failure of the operation control 
PWB and the MCU PWB
Check 
and 
remedy
Check the connectors and the harness of 
the operation control PWB and MCU PWB.
Check the grounding of the copier.
Check ROM on the operation control PWB.
80
Content
Operation control PWB communication 
trouble (Protocol)
Details
Communication trouble between MCU and 
the operation control PWB (Protocol error)
Cause
Operation control PWB connector 
disconnection.
Harness failure of the operation control. 
PWB and the MCU PWB.
Check 
and 
remedy
Check the connectors and the harness of 
the operation control PWB and MCU PWB.
Check the grounding of the copier.
Trouble 
code
Details of trouble
Main 
code
Sub 
code
Page of 127
Display