AR-M165-207 (serv.man17). Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 29

Read Sharp AR-M165-207 (serv.man17) Service Manual online

AR-M207 M165 M162 ADJUSTMENT 6-2
(3)Developing bias voltage check
Note: Use a digital multi-meter with an internal resistance of 10M
 or
more.
1) Set the digital multi-meter range to DC700V. 
2) Put the test rod of the digital multi-meter on the developing bias
voltage output check pin. 
3) Turn on the power, execute SIM25-1.
<Specification>
(4) Grid bias voltage check
Note: Use a digital multi-meter with an internal resistance of 10M
 or
more.
1) Set the digital multi-meter range to DC700V.
2) Put the test rod of the digital multi-meter on the grid bias voltage
output check pin. 
3) Turn on the power. 
(The voltage is outputted in the grid bias High output mode during
warming up, and in the grid bias Low output mode when warming up
is completed.)
<Specification>
B. Mechanism section
(1) Image position adjustment
a. OC image lead edge position adjustment (SIM 50-1)
Note: In advance to this adjustment, the sub scanning magnification ratio
adjustment must be performed.
1) Set a scale on the OC table as shown below.
2) Make a copy.
3) Check the copy output. If necessary, perform the following
adjustment procedures.
4) Execute SIM 50-01. 
Select a desired mode with the arrow keys, enter the adjustment
value with 10-key, and press [OK] key.
When [START] key is pressed, a sheet is printed.
When [RETURN] key is pressed, the process returns to the mode
selection window.
<Adjustment specification>
5) Set the OC lead edge position set value (RRC-A) to [1]
The OC image scanning start position is shifted inside the document
edge.
6) Set the main cassette lead edge void adjustment value (DEN-A)* to [1]
The lead edge void becomes the minimum.
Mode
 Specification
Developing bias voltage
 DC - 400±8V
Mode
 Specification
Grid bias LOW
 DC - 380±8V
Grid bias HIGH
 DC - 525±10V
Adjustment 
mode
 SIM
 Display 
text array
Set
 value
Spec
 value
 Set
range
OC image lead 
edge position
 SIM
50-1
RRC-A
R/0.1
Lead edge 
void:
1 - 4mm
Image loss: 
3mm or 
less
 1 - 99
Main cassette 
print start 
position
TRAY1
H/0.1
2nd cassette 
print start 
position
 TRAY2
Multi bypass 
tray print start 
position
 MFT
Lead edge void
DEN-A
B/0.05
(Mode selection window 1)
Sim50-1 LEAD EDGE
1:TRAY1
2:TRAY2
3:MFT
1/2     [      1-  99]
50
50
50
50
(Mode selection window 2)
Sim50-1 LEAD EDGE
4:DEN-A
5:RRC-A
6:DEN-B
2/2     [      1-  99]
50
1
50
50
Ready to copy.
S
100%
8 1/2X11
(Copy start window)
Copies in progress.
S
100%
8 1/2X11
(Copy execution window)
[06]ADJUSTMENT.fm  2 ページ  2004年11月12日 金曜日 午後2時13分
Page of 127