Read Sharp AR-LC9 Service Manual online
AR-LC9 ADJUSTMENTS 7 - 2
1) Enter the SIM 51-02 mode.
2) Select the “C: LCC” with the scroll key.
3) Enter the adjustment value with the 10-key.
• The smaller the set value is, the smaller the deflection quantity.
The greater the set value is, the greater the deflection quantity.
• Adjustment unit: Time in the unit of 1ms (The reference speed is
117mm/s. Variable according to the speed.)
4) Press the [OK] key.
The entered adjustment value is set.
ADJ 2
Resist amount adjustment
ADJ 2A
Adjustment in the resist amount
adjustment mode
adjustment mode
Display
Content
Set range
Default
C
LCC
Resist quantity adjustment
in high speed transport in
LCC paper feed.
in high speed transport in
LCC paper feed.
0 – 99
50