[11] EXPLANATION OF THE CIRCUITS
1. Operation
(1) Communication buffer circuit
On the communication buffer circuit, signals are input and output by the transistor array TD62504 (IC02).
(2) Sensor input circuit
The sensor signals used by LCC are connected directly to the input port of the IC02. LPFD is provided with a static electricity noise protective diode
which protects against static electricity from the paper transport section. The other sensors has the same circuit configuration as the LPED.
(3) Upper limit switch
A limit switch is provided to protect the LCC If it fails to operate normally. If the tray exceeds the upper limit sensor (LUD) position, the switch is
turned on to shut off the power of the lift motor.
2
P51/RXD
6
P46/CLK
1
P50/TXD
3
P52/SCK
3
14
2
15
12
5
10
7
CPU(IC01)
4.7K x 2
4.7K x 4
IC02C
IC02B
IC02E
IC02G
TD62504F
TD62504F
TD62504F
TD62504F
1SS133 x 4
D04
D05
D09
D10
D01
D02
D07
D08
1SS133 x 4
+5V
TXD-LCC
DTR-LCC/
RXD-LCC/
DSR-LCC/
CN-B-1
CN-B-3
CN-B2
CN-B-4
+5V
D23
1SS133
R94
22K
R95
22K
BR04
4.7K
38 LPFD
R79
10K
P21/A9
LPFD
CN-A-17
CPU
(IC01)
37 LDD
R80
10K
P22/A10
LDD
CN-A-23
39 LPED
R78
10K
P20/A8
LPED
CN-A-12
D24
1SS133
C14
C15
C16
1000P x 3
24V
24V(LLSW)
LLM+
LLM-
Upper limit switch
Lift motor
LCC control PWB
Lift motor
drive circuit
Signal name
Logic
DSR-LCC
H: Request for communication
L: No request for communication
DTR-LCC
H: Communication allowed
L: Communication inhibited
TXD-LCC
H: Normal
L: Start bit
RXD-LCC
H: Normal
L: Start bit
11 – 1
Page of 30
Display