AR-FX9  TEST COMMAND  3 - 2
4. Descriptions of various test commands
Main 
code
Sub 
code
Contents
Details of function/operation
22
11
FAX-related counter display
[Function]
The FAX-related counter is displayed.
[Operation]
24
10
FAX counter clear (FAX 
CLR.)
[Function]
When PRINT switch is pressed, the FAX count value is set to 0 and "000,000" is displayed on the
LCD.
[Operation]
46
12
Density adjustment in the 
FAX mode (Collective 
adjustment)
[Function]
When [START] key is pressed, scan is executed with the entered exposure adjustment value and the
data stored on the FAX side is rewritten into the entered value.
All data of the exposure adjustment values are rewritten into the same value.
For the density adjustment table data, refer to TC46-13 (density adjustment (normal text) in the FAX
mode).
[Operation]
1) Initial display
[CLEAR] key: Returns to the main-sub code
input display.
2) Select 1
("xxx,xxx" is the current value.)
[CLEAR] key: Returns to "1) Initial display".
2) Select 2
("xxxx: xxx. xx" is the current value.)
[CLEAR] key: Returns to "1) Initial display".
SELECT COUNTER
1:PAGE     2:TIME
SEND PAGE:xxx,xxx
RECV PAGE:xxx,xxx
TX TIME:xxxx:xx.xx
RX TIME:xxxx:xx.xx
1) Initial display
24-10 FAX CLR.
CLEARED       000,000
1) Initial display
("XX" is the exposure adjustment value of nor-
mal text stored on the FAX side.)
2) Enter a 2-digit value as the exposure adjust-
ment value.
("YY" is the entered exposure adjustment
value.)
3) Scan is started (self print), and the LED of
[START] key is turned off.
4) Print is started (self print).
After completion of printing, returns to “2)” dis-
play.
ADJUST  EXP.     AUTO
                   XX
ADJUST  EXP.     AUTO
                   YY
ADJUST  EXP.     AUTO
 SCAN             YY
ADJUST  EXP.     AUTO
 PRINT             YY
Page of 72
Display