AR-FX13  SPECIFICATIONS  2 - 5
Memory 
functions 
system
Memory outline
Memory capacity
Standard memory
2MB
Option
No
Document quantity to 
be stored
A4 standard documents 120 pages
Data storage area/ 
backup when service 
interruption (Recorded 
data, receive data)
Image data
Flash memory (Data are retained when the power is 
turned off or when the battery is exhausted.)
Data other than image
SRAM (Data are retained when the power is turned 
off, but deleted when the battery is exhausted with the 
power OFF.)
Treatment when 
memory full
Quick online
Memory full on the first 
page
Send cancel without call-out
Memory full on the 
second or later page
The line is shut-off after sending the last page of 
scanned data.
Memory send
Memory full on the first 
page
Send cancel
Memory full on the 
second or later page
Send/Cancel is selected depending on the select 
menu display.
Send: The line is shut off after sending the scanned 
data.
Cancel: Cancel even scanned data.
Memory status 
check function
Yes (The remaining memory capacity (%) is displayed 
on the LCD.)
Memory content 
check function
Not-sent job is displayed on the LCD. (Cancel is 
possible.)
Document jam
Error LED, LCD message are displayed.
Service 
functions 
system
Simulation 
function
Send/receive of specified signals, commands, and 
image data are performed without a remote machine.
Counter function
Communication 
counter
• Number of send pages
• Number of receive pages
• Number of output pages
• Send time
• Receive  time
Others
Environmental 
functions
Auto clear
Conforms to the main unit setting. When the 
operation is left for 1 min or more, the display returns 
to the main menu.
Auto shut -off
Conforms to the main unit setting.
Date and time 
setting function
(North America)
Month/ Day/ Year/ Day of week/ O'clock/ minute
(Europe, Australia, New Zealand)
Day/ Month/ Year/ Day of week/ O'clock/ minute
Image priority 
function
STANDARD/FINE/SUPER FINE
BEEP LENGTH 
(Communication 
end sound length) 
setting
3SEC/1SEC/NO BEEP
Auto summer time 
setting
(North America)
Second Sunday of March AM2:00 
→ 3:00,
First Sunday of November AM2:00 
→ 1:00
(Default: OFF)
(Europe)
Last Sunday of March AM1:00 
→ 2:00,
Last Sunday of October AM1:00 
→ 0:00
(Default: ON)
(Australia, New Zealand)
Last Sunday of October AM2:00 
→ 3:00,
Last Sunday of March AM3:00 
→ 2:00
(Default: ON)
Multi language 
function
Conforms to the main unit setting.
Large item
Middle item
Small item
Sub item
Specifications
Page of 72