1.Model Name:
AR-FN6
2.Description:
In some cases, the Staple Unit improperly contacts the Paper Guide due to incorrect
engagement of the Move Paper Guide A/B, Stopper 2, and Rotation Paper, resulting in
rotation failure of the stapler (F1-87). To prevent this problem from occurring, grease is
applied to each move paper guide and to the stopper 2.
3.Action:
From the 1st lot of September 2002 production.
MALFUNCTION OF STAPLER (F1-87)
TECHNICAL BULLETIN
Date:
19 February 2003
Model: ARFN6
Ref.:
013
Colour: White
Page:
1 of 3
ARE413b
Sharp Electronics (UK) Ltd., Technical Services Group
Parts code
Model
name
Current parts
New parts
Price
rank
Parts name
Effective
time
Inter-
change-
ability
AR-FN6
---
UKOG-0299FCZZ
GN
HANARL FL955R
2002/8
---
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
This measure is the fourth measure against rotation failure of the stapler.
The first three measures already reported are shown below for your reference.
Please take the necessary measure depending on the situation.
[First Corrective Action: T/R No. ARE-381-4]
When the staple cartridge was changed, stapler rotation could go wrong by, for example,
misoperation (F1-87). To prevent this, we changed the shape of the ST rotation plate and
added a ST lock plate A.
Action: From the 1st lot of March 2002 production.
Parts code
Model
name
P/G
No.
Current parts
New parts
Price
rank
Parts name
Effective
time
Inter-
change-
ability
 3-89
LPLTM5846FCZ1
LPLTM5846FCZ2
AL
Stable rotation
plate
AR-FN6
 3-
---
LPLTM6088FCZZ
AK
ST lock plate A
2002/3
5
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
ARE413b
Sharp Electronics (UK) Ltd., Technical Services Group
[Second Corrective Action: T/R No.ARE-386-5]
To improve the situation where F1-87 is indicated due to the incorrect rotation of Stapler,
the retry operation to correct the trouble was changed.
(1) In case that the Stapler does not correctly reach to the stapling position within the
predetermined period, the number of retry operation was changed from once to twice.
(2) In case that the Stapler does not reach to the correct stapling position if retried twice as
mentioned under the condition (1) above, the operation was changed such that the
Stapler is returned to the home position so that the Stapler moves to the correct stapling
position and it is rotated again (with three retry).
[Note] If the trouble like F1-87 is experienced during the copy job and the trouble is not
canceled in retry, the period of the jam timer is over during the job, so not F1-87 but the
Paper Jam is indicated.
Old
New
ROM Version
Ver 1.14
Ver 1.15
Action: From the 1st lot of June 2002 production.
[Third Corrective Action: T/R No. ARE-391-4]
To prevent the malfunction (F1-87) of the stapler from occurring due to the movable PG SP
coming off, the shape of the hook of movable PG SP was changed. (The length of the left
hook is increased by 8mm, and the length of the right hook is reduced by 1mm.)  Also,
please note that the shorter hook of the movable PG SP should be hooked to the movable
PG B/A ([3]-28/29) and the longer hook should be hooked to the alignment tray ([3]-18).
Action: From the 1st lot of July 2002 production
Parts code
Model
name
P/G No.
Current parts
New parts
Price
rank
Parts name
Effective
time
Inter-
change-
ability
AR-FN6
 3-49
MSPRT2932FCZZ
MSPRT2932FCZ1
AC
Move paper
guide spring
2002/7
3
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Page of 3
Display

Download Sharp AR-FN6 (serv.man16) Technical Bulletin

Here you can read online and download Sharp AR-FN6 (serv.man16) Technical Bulletin in PDF. AR-FN6 (serv.man16) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AR-FN6 (serv.man16) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.