AR-F200 (serv.man77). Parts change. (WHITE) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 14

Read Sharp AR-F200 (serv.man77) Technical Bulletin online

DCE158
Sharp Electronics (UK) Ltd., Technical Services Group
(2) For the models for Europe of 200V series of AR161 series, reactor and fixing screws
are added.
(3) For AR161 series, the PS PWB fixing plate is tapped (9 places).
Moreover, washer is added in order to protect the pattern of the high-voltage PWB.
(4) For ARF200 series, the parts code of the MCU PWB unit is changed.
P/G No.
Current parts
New parts
MCU PWB unit
12 -17
CPWBX0055QS53
CPWBX0055QS54
Changed content
Without jp5 cut
With jp5 cut
(5) For AR161 series, 2 kinds of aluminium sheet and flat washer are added in order to
satisfy the EMI standard.
Page of 19