AR-F200 (serv.man12). Replacement procedure for the polygon motor in the LSU unit. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp AR-F200 (serv.man12) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
DCE536
(5) Plug in the connector of the polygon motor and
insert it into the hole of the housing.
Notes:
 
Make sure that there is no damage, dust or
fingerprints on the mirror of the polygon motor.
 
Ground yourself to discharge static before
beginning work.
 
Make sure that the polygon motor is securely
mounted to the housing.
(6) Mount the polygon motor with the four M3 x 8P
tight screws.
Note:
 
Tighten the screws in order of 1-4 as shown in
the figure.
 
Be careful not to damage the mirror or lens by
the screwdriver when tightening the M3 x 8P
screws.
(7) Hold the LSU harness leaving no lifting.
Note: Make sure that the harness-retaining cushion
faces the same direction as it was before the
disassembly (with the notch facing up).
(8) Points to be checked.
 
Make sure that there is no damage or dust on the
mirror of the polygon motor.
 
The connector of the LSU harness must be
properly inserted.
 
Insert the harness-retaining cushion so that the
LSU harness shows no lifting.
 
Make sure that there is no dust inside the LSU.
(9) Mount the LSU cover to the housing.
Notes:
 
Do not apply any load to the LSU PWB.
 
Engage the 10 hooks one by one in the shown
direction.
 
Check that each hook is securely engaged by
pressing its upper part.
(10) Mount the LSU cover with two M3 x 8 star headed
screws. (A special screwdriver is required.)
Note: Do not over tighten the screws in order not to
lose their grip.
(11) Mount the LSU unit to the main unit.
Page of 4