AR-F200 (serv.man10). Information of parts change. 1 Fusing front PG change. 2 Cleaning blade change. 3 Roller pawl change. 4 Change of the AC switch to comply with RoHS. 5 Change of the line cable to comply with RoHS. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp AR-F200 (serv.man10) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
DCE562
2. Cleaning blade change.
1. Model Name
AR161/163/200/206/M160/M205
2. General
The cleaning blade has been changed to standardise with other models.
3. Content
Current parts
New parts
No
Model
name
Version
P/G
No.
Parts code
Parts code
Pric
e
rank
Parts
name
Effective
time
Inter-
change-
ability
Contents
1
*
1
ALL
 7  -3
UCLEZ0009QSZ1
UCLEZ0009QSZ2
AQ
Cleaning
blade
Running
change
from '04/9
3
<Interchange>
1. Interchangeable.
4. Not Interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related
parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones
for maintaining the safety and performance of the set.
Section 7 Process No.3 Cleaning blade.
3. Roller pawl change.
1. Model Name
AR161/163/200/205/206/F200/F201/M160/M165/M205/M207
2. General 
The roller pawl has been changed to standardise with other destinations.
3. Content
Current parts
New parts
No
Model
name
Version
P/G
No.
Parts code
Parts code
Pric
e
rank
Parts name
Effective
time
Inter-
change-
ability
Contents
*
1
10 -88
PTME-0032QSZZ
PTME-0032QSZ1
3
1
*
3
ALL
10 -8
PTME-0003QSZ1
PTME-0032QSZ1
AD
Roller pawl
'04/6
1
<Interchange>
1. Interchangeable.
4. Not Interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related
parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
Model Name *1 = AR161/163/200/206/M160/M205
Page of 4
Display

Click on the first or last page to see other AR-F200 (serv.man10) service manuals if exist.