Read Sharp AR-F16 (serv.man12) Technical Bulletin online
Sharp Electronics (UK) Ltd., Technical Services Group
1. Model Name: AR-F15/F16
2. Symptom:
The tray 1 may malfunction and the F1-02 trouble may occur owing to variations in micro
switches.
Explanation:
The micro switch is on during standby or when the electric power is off. The switch slider
moves when the tray 1 goes up during the machine initialization at power-on. The micro
switch turns off in conjunction with the switch slider movement.
However, owing to variation in micro switches, the micro switch whose turn-on position is at
the lower specification limit (the micro switch that does not turn on unless the switch lever is
pushed all the way in) may remain off only occasionally during standby. Consequently, the
tray 1 malfunctions and the F1-02 trouble occurs during the machine initialization at power-
on.
3. Description:
The shape of the switch slider to which the micro switch is attached has been modified
(change in the position of the micro switch positioning pins) so that the micro switch, including
the one whose turn-on position is at the lower specification limit, turns on with the switch
lever of the micro switch being pushed in completely.
4. Action:
From the mid-November 2006 production
MEASURES AGAINST F1-02 TROUBLE
(FINISHER TRANSFER MOTOR FAILURE).
Date:
12
th
June 2007
Model:
AR-F15/16
Ref.:
ARE 856
Colour:
White
Page:
1 of 2
TECHNICAL BULLETIN
5. Parts Action:
Current parts
New parts
Ref.
No.
Model
name
Version P/G No.
Parts code
Parts code
Price
rank
Parts name
Effective
time
Inter-
chan
ge-
abilit
y
Numbe
r
1
AR-F15
AR-F16
ALL
6-17 0CW4123R510// 0CW4123R510B/ AG SWITCH SLIDER
2006/11
Mid
3 1
<Interchange>
1. Interchangeable.
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Sharp Electronics (UK) Ltd., Technical Services Group
Display