AR-F12 (serv.man8). Maintenance, inspection and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AR-F12 (serv.man8) Service Manual online

7-3
CHAPTER 7   MAINTENANCE AND INSPECTION
IV. FIRMWARE UPDATING (only for inserter section)
The firmware updating can be automatically done by connecting the downloading jig to its own
connector and turning ON the power. The K-PWA-DLM-320 is used as a jig board.
1) Connect the inserter to the copier after the inserter rear cover is removed.
* At this time, do not connect the finisher interface cable to the inserter.
2) Connect the jig board to the connector on the inserter main board.
3) Turn the power ON with pressing the [3] and [9] keys of the copier. (The data starts to be updated
and the LED of the jig board turns ON.)
4) About 15 sec. later, the updating is finished and the LED of the jig board blinks to show the
result.
5) Turn the power OFF and take off the jig board.
* When failing to update, try again after turning OFF the power.
Table 7-401
[K-PWA-DLM-320]
Figure 7-401
Figure 7-402
LED
LED display
Result
(light ON period/light OFF period)
500msec/500msec
Success in updating
100msec/900msec
Wrong checksum with the updating EPROM
900msec/100msec
Failure in erasing the flash memory
Light-out
Failure in writing into the flash memory
1500msec/500msec
Success in writing into the flash memory but wrong
checksum with the flash memory
Page of 55
Display

Click on the first or last page to see other AR-F12 (serv.man8) service manuals if exist.