Read Sharp AR-F12 (serv.man8) Service Manual online
8-6
CHAPTER 8 TROUBLESHOOTING
8) Measure the distance (L) between the stitch-
ing position and the folding position. Then,
perform “positive width adjustment” or
“negative width adjustment” to suit the re-
lationship between the stitching position and
the folding position.
perform “positive width adjustment” or
“negative width adjustment” to suit the re-
lationship between the stitching position and
the folding position.
• If the stitching position is below the folding
position, perform “positive width adjust-
ment.”
ment.”
• If the stitching position is above the folding
position, perform “negative width adjust-
ment.”
ment.”
Mark
Mark
Folding position
Stitching position
Stitching position
Stitching position
Folding position
Folding position
Positive Width Adjustment
Negative Width Adjustment
Unit: mm
Example: If L is 1 mm, provide “+1 mm”.
Example: If L is 1 mm, provide “+1 mm”.
Unit: mm
Example: If L is 0.5 mm, provide “-0.5 mm”.
Example: If L is 0.5 mm, provide “-0.5 mm”.
Figure 8-116
9) Change the settings of bits 6 through 8 on
DIPSW1 referring to Table 7-102 below.
• If the width adjustment is “0”,
The stitching position and the folding posi-
tion match, requiring no change.
tion match, requiring no change.
• If for “positive width adjustment,”
Set DIPSW1 so that the difference result-
ing from subtraction of the interval from the
appropriate setting in Table 7-102 is pro-
vided.
For instance, if the DIPSW1 is currently set
to +2 and the interval is +1 mm, set
DIPSW1 to reflect -2.
ing from subtraction of the interval from the
appropriate setting in Table 7-102 is pro-
vided.
For instance, if the DIPSW1 is currently set
to +2 and the interval is +1 mm, set
DIPSW1 to reflect -2.
• If for “negative width adjustment”
Set DIPSW1 so that the sum resulting from
addition of the interval from the appropri-
ate setting is provided.
For instance, if the DIPSW1 is currently set
to -1 and the interval is +0.5 mm, set
DIPSW1 to reflect +1.
addition of the interval from the appropri-
ate setting is provided.
For instance, if the DIPSW1 is currently set
to -1 and the interval is +0.5 mm, set
DIPSW1 to reflect +1.
DIPSW1 bit settings
Settings
bit 6
bit 7
bit 8
(in units of 0.5 mm)
OFF
ON
ON
+3
OFF
ON
OFF
+2
OFF
OFF
ON
+1
OFF
OFF
OFF
0
ON
OFF
ON
−
1
ON
ON
OFF
−
2
ON
ON
ON
−
3
Do not touch the following:
bit 6
bit 7
bit 8
ON
OFF
OFF
Table 8-102
10) Set bits 1 through 4 on DIPSW1 to OFF.
2.
Stitching Position (adjusting center
stitching)
stitching)
Use the host machine adjustment mode to
perform the following:
Click on the first or last page to see other AR-F12 (serv.man8) service manuals if exist.