2-40
CHAPTER 2   FINISHER UNIT BASIC OPERATION
H.
Detecting the Height of Stack on the Tray
1.
Outline
The number of sheets delivered to the tray and the number of sets (number of stapling operations)
are stored in memory by the finisher controller PCB. The height of the stack is checked by the height
sensor (PS1). See Table 2-204 for the maximum loading capacity of each tray.
The finisher controller PCB stops operation when the conditions in Table 2-204 occur, informing
the host machine that the tray is full.
Stacking
mode
Height
Small-size
250 mm
high
(2000 sheets)
Large-size
140 mm
high
(1000 sheets)
Small-size
110 mm high
(750 sheets/
50 sets)
Non-staple sort
Staple sort
Mixed sizes
74 mm high
(500 sheets)
Large-size
74 mm high
(500 sheets/
50 sets)
Mixed sizes
22 mm high
(500 sheets/
50 sets)
Notes: 1.
The capacity for the non-staple sort mode is approximate and computed based on 80 g/m
2
 paper.
2.
Alignment for stacks containing 750 sheets or more is not guaranteed.
3.
Stacking height precision is ±7 mm.
Caution:
1. The term “small-size” stands for A4, LT, and B5.
2. The term “large-size” stands for A3, A4-R, B4, LG, LD, LT-R, FOLIO and
COMPUTER.
Table 2-204
Page of 58