(8) The addition of a rib has been carried out to the adjustment tray. This action has been
carried out as a measure to conform with the curvature regulations.
(9) The addition of a rib has been carried out to the small paddler. This action has been
carried out as a measure to prevent misalignment.
(10), (13)A change has been carried out in the pawl of the lock on the front door. This
action has been carried out as a measure to improve the locking performance of the
front door.
(11) A change has been carried out in the width of the rib of the actuator. This action has
been carried out as a measure to improve damage conditions of the leading edge of
the copy paper.
(12) A change has been carried out in the thickness (thinner) of the noise reduction sheet
in accordance with the shape of the actuator.