(2) Copy quality adjustment procedure flow
Perform the copy quality adjustment referring to the following work flow.
No
1
2
3
4
5
6
7
8
9
10
11
22 (Auto)/
20 (Manual)
22 (Auto)/
21 (Manual)
ADJ M9A
(ADJ M9)
ADJ M8
ADJ M7
ADJ M6
ADJ M5
ADJ M3
ADJ M9A
(ADJ M10)
JOB No
Work item
Simulation
When
installing
Repair (When a consumable part is replaced)/maintenance
After replacing
OPC drum (
1)
After replacing
developer (
2)
After replacing
transfer belt
After disposing
transfer section
waste toner

After cleaning
scanner
(reading) section
When in
periodic
maintenance
When in
repair/check
 (without replacing
consumable parts)
Toner concentration reference control level setup
Developer counter clear
OPC drum counter clear
Image density sensor adjustment
Image density sensor position adjustment
Image skew adjustment
OPC drum phase adjustment
Transfer section waste toner counter clear
Half-tone correction level is set to zero.
Main scan direction image resist adjustment
Sub scan direction image resist adjustment
25
24
24
44
44
64
44
24
44
50
50
2
5
7
13
23
1
20 (Old)/31 (New)
8
27
START
Perform ADJ1 CCD gamma adjustment.
SIM 63-03 (Normal document mode)
Copy color balance density check
(Check in the Text/Photo mode. ) (AR-C150)
(Check in the Text/Printed photo mode. ) (AR-C160/C250/C270)
(Test chart UKOG-0162FCZZ/UKOG-0283FCZZ is used.)
Are the copy
color balance and density
satisfactory ?
YES
NO
(Next page)
(Next page)
Is the CCD replaced?
YES
NO
Set the SIT chart
(UKOG-0280FCZZ) on
the original table.
Enter the SIM 63-03
mode and press the
EXECUTE key.
Copy color balance density check
(Check in the Text/Photo mode. ) (AR-C150)
(Check in the Text/Printed photo mode. ) (AR-C160/C250/C270)
(Test chart UKOG-0162FCZZ/UKOG-0283FCZZ is used.)
Process correction is forcibly
performed. (SIM 44-6)
Execute the half tone image
correction. (SIM 44-26)
The necessary work items for each condition are marked with " 
."
When replacing a consumable part, /when repairing or checking (without replacement of a consumable part) / 
when installing the machine, follow the work flow below. 
: Standard adjustment flow
7 –  26
Page of 21
Display

Click on the first or last page to see other AR-C270 (serv.man11) service manuals if exist.