AR-C250 (serv.man16). 073-Countermeasure for toner falling From process unit. - Sharp Copying Equipment Technical Bulletin (repair manual)

ar-c250 (serv.man16) technical bulletin
Model
AR-C250 (serv.man16)
Pages
5 Few pages! See other manuals at the bottom of the first or last page.
Size
1.07 MB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / 073-Countermeasure for toner falling From process unit.
File
ar-c250-sm16.pdf
Date

Read Sharp AR-C250 (serv.man16) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
CCE332
1.Model Name:
AR-C150/C250/C160/C270/330, AR-C15DU/25DU/33DU
2.Sympton:
Toner falling from the process unit may cause toner to adhere to the MC unit.
This toner adhesion may cause an abnormal electric discharge, resulting in a developer
leakage.
3.Description:
As a countermeasure to prevent toner falling, we have changed the shapes of side seals F
and R and have added side molts F and R and side seal mylar.
4.Action:
From mid-May 2006 production
Countermeasure for toner falling
From process unit.
TECHNICAL BULLETIN
Date:
25 January 2007
Model: 
ARC250
Ref.:
073
Colour: 
White
Page:
1 of 5
Sharp Electronics (UK) Ltd., Technical Services Group
CCE332
5.Parts Action:
Current parts
New parts
Ref.
No.
Model
name
Version P/G No.
Parts code
Parts code
Price
rank
Parts name
Effective
time
Inter-
change
-
ability
Number
16-12
PSEL-0909FCZ1
PSEL-0909FCZ2
Side seal R
16-14
PSEL-0910FCZ1
PSEL-0910FCZ2
AF
Side seal F
3
16-
---
PMLT-1579FCZZ
Side molt R
16-
---
PMLT-1580FCZZ
AA
Side molt F
1
1
AR-C150
AR-C250
AR-C160
AR-C270
AR-C330
ALL
16-
---
PSHEP5054FCZZ
AC
Side seal mylar
2006/5
Mid
---
2
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Sharp Electronics (UK) Ltd., Technical Services Group
CCE332
Front side
(1) Attachment of side molt form F
1. Clean the part on the process frame where the side molt form will be attached with alcohol.
2. Align the attachment criteria "a" and "b" of the side molt form F and "A" and "B" of the process frame
when attaching them.
3. Attach carefully to make no gap between the side molt form F and the frame at the attachment criteria
of A (a)-side.
(2) Attachment of side seal mylar
1. Clean the part where the side seal mylar will be attached with alcohol.
2. Align the attachment criteria "c" and "d" of the side seal mylar and "C" and "D" of the process frame
when attaching them.
3. The tolerance of the attachment criteria is within 0mm to 0.5mm.
(3) Attachment of side seal F
1. Clean the part where the side seal F will be attached with alcohol.
2. Align the attachment criteria "e" and "f" of the side seal F and "E" and "F" of the process frame when attaching
them.
3. Please make sure to attach the blue part in the diagram below to side G of the process frame.
Sharp Electronics (UK) Ltd., Technical Services Group
CCE332
Rear side
(1) Attachment of side molt form R
1. Clean the part on the process frame where the side molt form will be attached with alcohol.
2. Align the attachment criteria "a" and "b" of the side molt form R and "A" and "B" of the process frame
when attaching them.
3. Attach carefully to make no gap between the attachment surfaces of the side molt form R and the process
frame.
(2) Attachment of side seal mylar
1. Clean the part where the side seal mylar will be attached with alcohol.
2. Align the attachment criteria "c" and "d" of the side seal mylar and "C" and "D" of the process frame
when attaching them.
3. The tolerance of the attachment criteria is within 0mm to 0.5mm.
(3) Attachment of side seal R
1. Clean the part where the side seal R will be attached with alcohol.
2. Align the attachment criteria "e" and "f" of the side seal R and "E" and "F" of the process frame when
attaching them.
3. Please make sure to attach the blue part in the diagram below to side G of the process frame.
(Points to be checked)
(1) Check the gap between the side seals (F and R) and the blade.
Confirm that the blade doesn't touch the side seal F or R by pressing the blade.
Page of 5
Display

Download Sharp AR-C250 (serv.man16) Technical Bulletin

Here you can read online and download Sharp AR-C250 (serv.man16) Technical Bulletin in PDF. AR-C250 (serv.man16) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AR-C250 (serv.man16) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.