AR-C170M  DESCRIPTIONS OF EACH SECTION  7 - 3
d. Fusing temperature control
The temperature sensor is provided at the center of the upper and
the lower heat rollers.
The temperature sensor at the center detects the heat roller tem-
perature and controls the heater lamp to keep the fusing tempera-
ture at the specified level.
The fusing temperature is switched according to the machine con-
dition and paper type selected.
(Example: 200V series)
B. Disassembly/Assembly/Maintenance
(1) Fusing section maintenance target parts
: Check (Clean, replace, or adjust as necessary.)
 
: Clean
 
: Replace
 
: Adjust
 
: Lubricate
 
: Shift position
Upper heat roller
Lower heat roller
Ready state
160°C
145°C
Power save mode
138°C
OFF
Print mode
Normal paper 
B/W
160°C
145°C
OHP sheet
170°C
155°C
Heavy paper 1
170°C
135°C
Heavy paper 2
175°C
145°C
Envelope
180°C
145°C
Unit name
No.
Part name
When 
calling
50K
100K
150K
200K
250K
300K
350K
400K
Remark
Fusing section
1
Upper heat roller
Replace at 100K or 
within 2 years.
2
Lower heat roller
Replace at 100K or 
within 2 years.
3
Heat roller gear
100K
4
Heat roller bearing
100K
5
Separation pawl
100K
6
Thermistor
100K
Bearings
7
Gears
8
Paper guides
9
Paper exit roller
Fusing unit
Replace the unit at 
100K or within 2 years.
6
6
1
2
4
4
4
4
5
8
9
3
6
6
1
2
5
4
4
4
4
5
9
7
8
3
Page of 56