AR-C150 (serv.man4). ARC150 250-Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 117

Read Sharp AR-C150 (serv.man4) Service Manual online

Note
Never set to another value than the specified value (de-
fault). (Otherwise, a trouble may occur.)
43 - 7
Purpose
Adjustment
Function
(Purpose)
Used to adjust the fusing oil supply amount. (Adjust-
ment of oil motor ON time and oil motor ON interval)
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the adjustment item with [
], [
] keys.
A: ON-TIME
Fusing oil pump ON time [ms]
B: CTRL-CYCLE
Fusing oil pump control cycle [ms]
2. Enter the set value with the 10-key.
3. Press the [OK] key.
When the [EXECUTE] key is pressed, it is highlighted and the
pump is operated with the set content.
When the [EXECUTE] key is pressed again, the display returns
to the normal display and the pump is stopped.
Range [ms]
Default value
ON-TIME
5 –  50
12
CTRL-CYCLE
17 –  250
130
(Example) When ON-TIME is 12ms and CTRL-CYCLE is 250ms,
12ms of ON and (250+50) – 12ms of OFF are re-
peated.
Default
A: ON-TIME
12 [ms]
B: CTRL-CYCLE
130 [ms]
When installing (replacing) this pump, set the pump operation
value of Sim 43-7 referring to the marking color shown in the illus-
tration below.
Marking color
Setting of simulation 43-7
A
B
Blue
12
80
Red
12
180
None
12
130
44
44 - 4
Purpose
Setting
Function
(Purpose)
Used to set the target image (reference) density level in
correction (process correction) operations in the image
forming section.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Picture quality
Density
Operation/
Procedure
1. Select the adjustment item with [
], [
] keys.
2. Enter the set value with 10-key. 
(255 levels)
3. Press the [OK] key. (The value entered in procedure 2 is set.)
Default value
Color sensor adjustment
reference level
PCS_C_TARGET_ID
102
Black sensor adjustment
reference level
PCS_B_TARGET_ID
133
Yellow reference density
level
Y_PAT_TARGET_ID
90
Magenta reference
density level
M_PAT_TARGET_ID
100
Cyan reference density
level
C_PAT_TARGET_ID
83
Black reference density
level
K_PAT_TARGET_ID
15
(AR-C100/C150)
Black reference density
level
K_PAT_TARGET_ID
22
(AR-C250/C160/
C270)
Marking