Read Sharp AR-C150 (serv.man4) Service Manual online
Note
Never set to another value than the specified value (de-
fault). (Otherwise, a trouble may occur.)
fault). (Otherwise, a trouble may occur.)
43 - 7
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the fusing oil supply amount. (Adjust-
ment of oil motor ON time and oil motor ON interval)
ment of oil motor ON time and oil motor ON interval)
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
Procedure
1. Select the adjustment item with [
↑
], [
↓
] keys.
A: ON-TIME
Fusing oil pump ON time [ms]
B: CTRL-CYCLE
Fusing oil pump control cycle [ms]
2. Enter the set value with the 10-key.
3. Press the [OK] key.
When the [EXECUTE] key is pressed, it is highlighted and the
pump is operated with the set content.
When the [EXECUTE] key is pressed again, the display returns
to the normal display and the pump is stopped.
pump is operated with the set content.
When the [EXECUTE] key is pressed again, the display returns
to the normal display and the pump is stopped.
Range [ms]
Default value
ON-TIME
5 – 50
12
CTRL-CYCLE
17 – 250
130
(Example) When ON-TIME is 12ms and CTRL-CYCLE is 250ms,
12ms of ON and (250+50) – 12ms of OFF are re-
peated.
peated.
Default
A: ON-TIME
12 [ms]
B: CTRL-CYCLE
130 [ms]
When installing (replacing) this pump, set the pump operation
value of Sim 43-7 referring to the marking color shown in the illus-
tration below.
value of Sim 43-7 referring to the marking color shown in the illus-
tration below.
Marking color
Setting of simulation 43-7
A
B
Blue
12
80
Red
12
180
None
12
130
44
44 - 4
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the target image (reference) density level in
correction (process correction) operations in the image
forming section.
correction (process correction) operations in the image
forming section.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Cleaning)
Item
Picture quality
Density
Operation/
Procedure
Procedure
1. Select the adjustment item with [
↑
], [
↓
] keys.
2. Enter the set value with 10-key.
(255 levels)
3. Press the [OK] key. (The value entered in procedure 2 is set.)
Default value
Color sensor adjustment
reference level
Color sensor adjustment
reference level
PCS_C_TARGET_ID
102
Black sensor adjustment
reference level
reference level
PCS_B_TARGET_ID
133
Yellow reference density
level
level
Y_PAT_TARGET_ID
90
Magenta reference
density level
density level
M_PAT_TARGET_ID
100
Cyan reference density
level
level
C_PAT_TARGET_ID
83
Black reference density
level
level
K_PAT_TARGET_ID
15
(AR-C100/C150)
Black reference density
level
level
K_PAT_TARGET_ID
22
(AR-C250/C160/
C270)
Marking
8 – 18
Click on the first or last page to see other AR-C150 (serv.man4) service manuals if exist.