AR-C150 (serv.man18). 102-Countermeasure for toner falling From process unit. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp AR-C150 (serv.man18) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
CCE332
Front side
(1) Attachment of side molt form F
1. Clean the part on the process frame where the side molt form will be attached with alcohol.
2. Align the attachment criteria "a" and "b" of the side molt form F and "A" and "B" of the process frame
when attaching them.
3. Attach carefully to make no gap between the side molt form F and the frame at the attachment criteria
of A (a)-side.
(2) Attachment of side seal mylar
1. Clean the part where the side seal mylar will be attached with alcohol.
2. Align the attachment criteria "c" and "d" of the side seal mylar and "C" and "D" of the process frame
when attaching them.
3. The tolerance of the attachment criteria is within 0mm to 0.5mm.
(3) Attachment of side seal F
1. Clean the part where the side seal F will be attached with alcohol.
2. Align the attachment criteria "e" and "f" of the side seal F and "E" and "F" of the process frame when attaching
them.
3. Please make sure to attach the blue part in the diagram below to side G of the process frame.
Page of 5