AR-651/810 UNPACKING AND INSTALLATION 19 - 8
56) PLUG IN
57) INSTALL
58) ADJUSTMENT
Adjustment of the Auto-Toner Sensor
(1) While pressing keys [0] and [5]
simultaneously, turn on the power switch to
show [100% TEST MODE A] on the
message display.
show [100% TEST MODE A] on the
message display.
(2) Key in code “200” and press the START key.
The copier will start operating, and certain
values will appear in Zones “A” and “B”.
values will appear in Zones “A” and “B”.
(3) About 2 minutes later, the values in Zone “B”
will start changing.
(4) After a short time, the value in Zone “B” will
automatically stop changing and, at the
same time, the message will also change as
shown below.
same time, the message will also change as
shown below.
(5) In this status, check that the value in Zone
“B” is in the range of 245 to 255 (auto-toner
sensor output range of 2.45V to 2.55V).
sensor output range of 2.45V to 2.55V).
(6) If the value in Zone “B” is in not in the range
of 245 to 255, use the [
Down] / [
Up]
keys to adjust the value.
(7) Press the [SET] key. The message display
will return to [100% TEST MODE A].
(8) Key in code “290” and press the START key.
The copier will start operating. The message
display will return to WAIT.
display will return to WAIT.
(9) About 1 minute later, the copier will stop
operating. The message display will return
to TEST MODE.
to TEST MODE.
(10) Turn OFF the power switch to finish the
adjustment.
* Do not turn it on again.