AR-651/810  DEVELOPER UNIT  12 - 8
<Control signals>
(1) DEVCK signal (LGC   DEV-MOT: input)
This signal is a reference clock signal for the developer motor to rotate at a fixed speed. The frequency
of the reference clock is 821.2Hz.
When the cycle of the FG pulse deviation from the reference frequency is within +6.25%, this state is
specified as lock range (normal rotation). Also, at this time, the LED “D4” light comes ON.
(2) DEVON signal (LGC   DEV-MOT: input)
This signal is the motor ON/OFF control signal. When it becomes “L” level, the motor rotates.
Signal level for motor circuit
Signal
“H” level
“L” level
DEVCK             Reference clock (821.2Hz)
DEVON
Motor OFF
Motor ON