AR-810 (serv.man15). Drum cleaner unit - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-810 (serv.man15) Service Manual online

AR-651/810  DRUM/CLEANER UNIT  11 - 8
Recovery blade
A
Recovery blade
Cleaner flame
Drum surface
Cleaning brush
Holding shaft
Plate
[D]  Recovery blade
(1) Remove the recovery blade.
Notes: 1. The recovery blade is attached with a
double-faced tape, so remove the tape
completely before attaching a new blade.
2. Attach the recovery blade fitting its
bottom edge into the notch of the cleaner
frame.
[E]  Cleaning brush
(1) Pull out the rear side holding shaft and take
off the cleaning brush.
[F]  Drum separation finger
(1) Remove 2 screws and take off the plate at the
rear side.
Page of 10