AR-810 (serv.man14). Process section - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp AR-810 (serv.man14) Service Manual online

AR-651/810  PROCESS SECTION  10 - 10
45
A
[D]  Ozone filter
(1) Remove 1 screw and pull out the ozone filter
at the exit side.
[C]  Discharge lamp
(1) Remove the main charger and cleaner unit.
(2) Disconnect 1 connector, remove 1 screw
and take off the discharge lamp.
Connector
(3) Disconnect 1 connector, remove 2 screws and
take off the wire cleaner drive motor with the
bracket.
(4) Remove 2 screws and take off the motor.
Wire cleaner drive motor
(5) Disconnect 2 connectors, remove 1 screw and
take off the wire cleaner stop position switch.
Note: When installing the switch, fix it with pushing it
toward the arrow 
. Also, pay attention to the
color of the harness when connecting the
connectors to the terminals,  and then bend the
terminals  45 degrees.
Connector
Black
Purple