Read Sharp AR-651 (serv.man19) Service Manual online
AR-651/810 RADF (DOCUMENT FEEDER) 16 - 80
(5) Disconnect 1 connector and take off the lifting
tray lower limit sensor.
(3) Open the reverse guide, detach the front side
inlet and take off the guide toward the front
side.
(4) Remove 4 screws and take off the lower
guide.
(G-2) Lifting tray lower limit sensor
(1) Remove the upper guide unit.
(2) Remove 2 screws and take off the upper
guide stay.
Lifting tray lower limit sensor
Inlet
Reverse guide
Lower guide
Upper guide stay
[G] Sensors/Switches
(G-1) Lifting tray upper limit sensor/Empty sensor/
Cover open/close sensor
(1) Open the jam access cover, remove 2 screws
and take off the upper guide cover.
(2) Disconnect the connectors and release the
latches and take off the lifting tray upper limit
sensor, empty sensor and cover open/close
sensor.
Cover open/close sensor
Empty sensor
Lifting tray upper
limit sensor
limit sensor
Click on the first or last page to see other AR-651 (serv.man19) service manuals if exist.