Read Sharp AR-651 (serv.man19) Service Manual online
AR-651/810 RADF (DOCUMENT FEEDER) 16 - 17
The small original exit motor starts to rotate forward. Then it starts to slow down with a specified time
delay after the small original reverse sensor has detected the leading edge of the original.
The small original exit motor stops rotating when the trailing edge of the original has been detected by
the small original exit sensor then proceeded a specified distance. The small original exit solenoid turns
OFF and the operation ends when the original has been discharged.