AR-651 (serv.man16). Transfer transporter unit - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp AR-651 (serv.man16) Service Manual online

AR-651/810  TRANSFER/TRANSPORT UNIT  13 - 7
[F]  Transfer/Transport unit
(1) Open the front cover, turn the lever clockwise
and pull out the transfer/transport unit.
(2) Remove the fuser unit and transfer belt.
Note: When removing the transfer/transport unit,
remove each unit after removing the fuser and
transfer belt units.
(3) Remove 2 shoulder screws fixed at both sides
slide rails.
(4) Hold the A(shaft) or B(stay) section with the left
hand and the right slide rail with the right hand.
[E]  Damp heater
(1) Remove the transfer belt unit.
(2) Remove 2 screws, disconnect 1 connector and
take off the damp heater.
Note: When installing the dump heater, be careful
not to catch it  in the harness.
A
B
Dump
heater
Connector
Page of 10