AR-651 (serv.man14). Drum cleaner unit - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp AR-651 (serv.man14) Service Manual online

AR-651/810  DRUM/CLEANER UNIT  11 - 9
E-ring
Cam
Separation finger
(2) Remove 1 E-ring and take off the cam.
(3) Move the shaft of the separation finger toward
the rear side and pull it out.
(4) Remove the screws and pull out the
separation fingers from the shaft.
[G]  Image quality sensor
(1) Remove 2 screws and take off the sensor with
the bracket.
(2) Remove 2 screws and take off the image
quality sensor.
Connector
Page of 10
Display