2. Copier adjustment
A. Process section 
(1) Developing doctor gap adjustment
1) Remove the screw and the connector which connect the toner
hopper and the developing unit, and separate them. 
2) Loosen the DV doctor fixing screw A.
3) Insert a thickness gauge (0.6mm) into the clearance of 40mm 
70mm from the DV doctor edge.
4) Press the DV doctor in the arrow direction and tighten the DV
doctor fixing screw. (Perform the same procedure for the front and
the rear frame.)
5) Check that the clearance (2 positions) at 40mm 
 70mm from the
both ends is 0.6 
±
 0.03mm. 
*
When inserting a thickness gauge, be careful not to scratch the
DV doctor and the MG roller. 
(2) MG roller main pole position adjustment
1) Remove the screw and the connector which connect the toner
hopper and the developing unit, and separate them. Put the
developing unit on a flat floor. 
2) Tie a needle or pin on a string. 
3) Hold the string and put the needle horizontally and move it toward
the MG roller. (Do not use a clip which is too big to have a correct
position since the MG roller diameter is small.)
4) With the needle tip at 2 
 3 mm apart  from  the MG roller surface,
mark the point on the surface which is on the extended line of the
needle tip. 
5) Measure the distance between the marking position and surface P
of the developing unit and check that it is 17mm.
If the distance is not as specified above, loosen the fixing screw A
of the main pole adjustment plate, and move the adjustment plate
to adjust. 
30mm
40mm
40mm
30mm
A
17.0mm
2~3mm
P
2~3mm
17.0mm
AR-405
1/21/1999
7 – 2
Page of 18