2) Disconnect the connector from the CN9 on the control PWB, and
connect the short connector (OCW4074K526//) instead.
3) Remove the ADF/RADF top cover, and set the DIP switch on the
control PWB to the desired test mode. While pressing the push
switch ON, turn on the power of the machine. 
(With the above operation, the machine enters the test mode.)
4) Turn on the push switch on the control PWB.
(Test operation is started.)
(To switch to another test mode, set the DIP switch on the control
PWB to the desired test mode, and open/close the ADF/RADF paper
feed section cover (microswitch FGOD it turned OFF and ON).
DIP switch 3 meaning
ON
OFF
DIP switch 3
For AB series
For inch series
Kinds of test modes and setting of DIP switch
No.
Test mode name
DIP switch
a
Single paper pass mode
All OFF
b
Duplex paper pass mode
1 ON,
the others OFF
c
Single aging mode
1, 3 ON,
2, 4, 5 OFF
d
Duplex aging mode
4 ON,
the others OFF
e
Load check mode
1, 5 ON,
2, 3, 4, OFF
f
EEPROM initializing mode + all
sensors adjustment mode
3, 5 ON,
1, 2, 4, OFF
g
Resist sensor adjustment mode
4, 5 ON,
1, 2, 3, OFF
h
Timing sensor adjustment mode
1, 4, 5, ON,
2, 3, OFF
i
Paper exit sensor adjustment mode
(AR-RF1 only)
3, 4, 5, ON,
1, 2, OFF
a. Single paper pass mode (with paper)
When documents are set on the paper feed tray, the document feed
LED lights up. When the push switch is pressed, all documents on the
paper feed tray are fed.
b. Duplex paper pass mode (with paper)
When documents are set on the paper feed tray, the document feed
LED lights up. When the push switch is pressed, all documents on the
paper feed tray are fed.
c. Single aging mode (without paper)
When the push switch is pressed, aging is started. The operation
timing is made by detection of each document size on the tray.  
d. Duplex aging mode (without paper)
When the push switch is pressed, aging is started. The operation
timing is made by detection of each document size on the tray.  
e. Load check mode
Set the DIP switch on the contro PWB as shown below, and open
and close the ADF/ RADF paper feed section cover to enter the load
check mode.
(DIP switch)
Every time when the push switch is pressed, the operation is per-
formed in the sequence of 1) 
 21)
 1) Document feed LED ON, Document remain LED ON, Paper
feed solenoid ON
  2) Reverse solenoid ON, Paper feed solenoid OFF
  3) Document feed LED OFF, Document remain LED OFF, Reverse
solenoid OFF
 4) Document feed LED ON, Document remain LED OFF, Paper
feed solenoid ON, Paper feed motor forward rotation 450mm/s
(Preliminary paper feed operation)
  5) Document feed LED OFF, Document remain LED OFF, Paper
feed solenoid OFF, Paper feed motor OFF
 6) Document feed LED ON, Document remain LED ON, Paper
feed motor reverse rotation 450mm/2 (2-step advanced feed)
  7) Document feed LED OFF, Document remain LED OFF, Paper
feed motor OFF
 8) Document feed LED ON, Document remain LED ON, Paper
feed motor reverse rotation 850mm/s (Paper feed operation)
  9) Document feed LED OFF, Document remain LED OFF, Paper
feed motor OFF
10) Document feed LED ON, Document remain LED ON, Transport
motor forward rotation 867mm/s
11) Document feed LED OFF, Document remain LED OFF,
Transport motor OFF
12) Document feed LED ON, Document remain LED ON, Transport
motor reverse rotation 867mm/s
13) Document feed LED OFF, Document remain LED OFF,
Transport motor OFF
14) Document feed LED ON, Document remain LED ON, Reverse
motor forward rotation 867mm/s (reverse operatoin)
15) Document feed LED OFF, Document remain LED OFF, Reverse
motor OFF
16) Document feed LED ON, Document remain LED ON, Reverse
motor forward rotation 867mm/s (Pulling/paper exit operation)
1)
2)
OFF
ON
SW
No.1
2
3
4
5
AR-405