AR-405 (serv.man132). Report Of Flash Memory Version Method. (WHITE) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 6

Read Sharp AR-405 (serv.man132) Technical Bulletin online

Message display
Contents
Causes and countermeasure
Failed to initialize ASPI manager
The initialization of the ASPI manager
has failed.
The ASPI manager has not been
installed properly.
No valid firmware installed.
No effective ROM file exists.
The type of the ROM file does not
match the type of the Flash ROM
inserted in the socket.
Invalid firmware is installed.
The checksum described in the FD file
does not match the checksum contained
in the MOT file.
Check the checksums in both FD and
MOT files.
Translation of firmware has
incompleted.
Communication error:
A problem occurred while transmitting
the ROM data.
Check the SCSI connection.
No valid copier connected.
Communication error:
A problem occurred while confirming the
connection with the Copier.
The PC does not recognize the Copier
as a SCSI device. Check the Sim26-44
settings. Check the connection channel.
Check the installation of the SCSI driver
and ASPI driver on the PC.
Failed to allocate memory.
Insufficient memory was allocated to run
the FLASH4.EXE file.
Memory of the PC was insufficient.
Firmware update has incompleted.
The rewrite to the flash memory has
failed.
If you tried rewriting flash ROM data two
or more times by clicking on “Transmit”
and both attempts failed, there is a
possibility that the FLASH ROM was not
installed properly or it may be defective.
ARE160
Sharp Electronics (UK) Ltd., Technical Services Group
Error messages
Page of 6
Display