Read Sharp AR-337 (serv.man89) Regulatory Data online
S H A R P
Data Revised :
Date Issued : Feb. 1, 1999
Date Issued : Feb. 1, 1999
MATERIAL SAFETY DATA SHEET (1/2)
MSDS No. F-30891
Section 1. Product Identification
Product
AR-336ND / AR-336SD / AR-336DV (Black Developer) For use with : AR-250, AR-286, AR-287, AR-336, AR-337
AR-336ND / AR-336SD / AR-336DV (Black Developer) For use with : AR-250, AR-286, AR-287, AR-336, AR-337
Section 2. Supplier's Name and Address
Sharp Corporation
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
Local suppliers are listed below. Please contact the nearest supplier for additional information.
(Country)
(Name and Telephone Number)
U.S.A.
Sharp Electronics Corporation
Telephone number for information :1-800-237-4277
Emergency telephone number :1-800-255-3924
Telephone number for information :1-800-237-4277
Emergency telephone number :1-800-255-3924
Canada
Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number :1-800-255-3924
Telephone number for information : 905-890-2100
Emergency telephone number :1-800-255-3924
United
Kingdom
Kingdom
Sharp Electronics (U.K.) Ltd.
Telephone number for information : 01923 474013
Telephone number for information : 01923 474013
Section 3. Ingredients
Ingredients
CAS No.
Proportion
OSHA PEL
ACGIH TLV
Other Limits
Ferrite
>95%
Not listed
Not listed
None
Iron oxide
1309-37-1
Iron oxide
1317-61-9
Magnesium oxide
1309-48-4
Bisphenol A type polyester resin
213077-22-6
< 4%
Not listed
Not listed
None
Carbon black
1333-86-4
<0.4%
3.5mg/m
3
3.5mg/m
3
None
Section 4. Hazardous Identification (Emergency Overview)
Developer is a black powder containing small amounts of toner, and possessing no immediate hazard. There are no
anticipated carcinogenic effects from exposure based on animal tests performed using toner.
anticipated carcinogenic effects from exposure based on animal tests performed using toner.
Section 5. Health Hazard Data
Route(s) of Entry :
Inhalation?
Skin?
Ingestion?
No
No
Possible but very unusual.
Health Hazards :
Acute oral toxicity --- LDL
0
of this toner which is included in this developer is
over 2,000mg/kg.
Mutagenicity --- The toner, which is included in this developer, has been tested
on Ames test. The result is negative.
Carcinogenicity :
In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human
carcinogen). This classification is given to chemicals for which there is inadequate human
evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The
classification is based upon the development of lung tumors in rats receiving chronic
inhalation exposures to free carbon black at levels that induce particle overload of the lung.
Studies performed in animal models other than rats did not show any association between
carbon black and lung tumors. While there have been no studies to date using developer, a
two-year cancer bioassay using a typical toner preparation containing carbon black (a small
amount of toner is included in the developer mixture) demonstrated no association between
toner exposure and tumor development in rats.
carcinogen). This classification is given to chemicals for which there is inadequate human
evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The
classification is based upon the development of lung tumors in rats receiving chronic
inhalation exposures to free carbon black at levels that induce particle overload of the lung.
Studies performed in animal models other than rats did not show any association between
carbon black and lung tumors. While there have been no studies to date using developer, a
two-year cancer bioassay using a typical toner preparation containing carbon black (a small
amount of toner is included in the developer mixture) demonstrated no association between
toner exposure and tumor development in rats.
Signs and Symptoms of Exposure
: Minimal irritation to respiratory tract may occur as with
exposure to any non-toxic dust.
exposure to any non-toxic dust.
Medical Conditions Generally Aggravated by Exposure : None
S H A R P
Data Revised :
Date Issued : Feb. 1, 1999
Date Issued : Feb. 1, 1999
MATERIAL SAFETY DATA SHEET (2/2)
MSDS No. F-30891
Section 5. Health Hazard Data (Continued)
Emergency and First Aid Procedures :
Inhalation ; Remove to fresh air. If effects occur, consult medical personnel.
Eye ; In case of contact, immediately flush eyes with water for 15 minutes.
Eye ; In case of contact, immediately flush eyes with water for 15 minutes.
Section 6. Physical Chemical Characteristics
Boiling / Melting Point
: Not applicable
Specific Gravity
: about 5
Vapor Pressure
: Not applicable
Solubility in Water
: Negligible
Vapor Density
: Not applicable
PH
: Not applicable
Evaporation Rate
: Not applicable
Viscosity
: Not applicable
Appearance
: Fine powder
Color
: Black
Odor
: Odorless
Section 7. Fire and Explosion Data
Flash Point (Method Used)
:
Not applicable
Ignition Temperature
:
>350
0
C
Flammable Limits
:
(LEL); Not applicable
(UEL); Not applicable
Extinguishing Media
:
CO2, dry chemical, foam or water
Special Fire Fighting Procedure
:
None
Unusual Fire and Explosion Hazard
:
This material has no unusual fire or explosion hazards.
Sensitivity to Mechanical Impact
:
None
Sensitivity to Static Charge
:
None
Section 8. Reactivity Data
Stability
:
Stable
Incompatibility (Material to Avoid)
:
None
Hazardous Decomposition
:
CO and NOx
Hazardous Polymerization
:
Will not occur.
Section 9. Precautions for Safe Handling and Use
Personal Protection Information (Respiratory, Eye Protection and Protective Glove):
None required under normal use.
Engineering Control / Ventilation
:
Not required.
Work / Hygienic Practice
:
Not required.
Steps to be taken in case of Spill or Leak :
Sweep up or clean up with vacuum cleaner.
Waste Disposal Method
:
Waste material may be dumped or incinerated under conditions
which meet all federal, state and local environmental regulations.
Section 10. Regulatory Information
NFPA Rating (U.S.A.)
:
Health = 1
Flammability = 1
Reactivity = 0
WHMIS Legislation (Canada)
:
This product is not a controlled product.
Transport Information
:
This product is not a hazardous material.
UN No.
:
None allocated.
Section 11. Other Information
References : IARC (1996) IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
Humans, Vol. 65, Printing Process and Printing inks, Carbon Black and Some Nitro Compounds, Lyon, pp-149-261
H. Muhle, B. Bellmann, O. Creutzenberg, C. Dasenbrock, H. Ernst, R. Kilpper, J. C. MacKenzie,
P. Morrow, U. Mohr, S. Takenaka, and R. Mermelstein (1991) Pulmonary Response to Toner upon Chronic
Inhalation Exposure in Rats. Fundamental and Applied Toxicology 17, pp. 280-299
Humans, Vol. 65, Printing Process and Printing inks, Carbon Black and Some Nitro Compounds, Lyon, pp-149-261
H. Muhle, B. Bellmann, O. Creutzenberg, C. Dasenbrock, H. Ernst, R. Kilpper, J. C. MacKenzie,
P. Morrow, U. Mohr, S. Takenaka, and R. Mermelstein (1991) Pulmonary Response to Toner upon Chronic
Inhalation Exposure in Rats. Fundamental and Applied Toxicology 17, pp. 280-299