AR-337 (serv.man4). AR287 337 407 507-Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 3

Read Sharp AR-337 (serv.man4) Service Manual online

AR-286/336/405/505
AR-287/337/407/507
Section
Page
Content
Change
Remark
[6]
6-5
(5) Transfer charger current adjustment
(5) Transfer charger current adjustment
(6) Separation charger DC component voltage
(6) Separation charger DC component voltage
[7]
SIMULATION
B. List
C. Details of simulations
 8-1
 8-2
 8-6
 8-7
 22-1
 26-10/12/13 
 26-22 
 26/32 
 26-44
 26-52 
 50-1/2
 50-26
 51-3
 61-2/4 
 67-18
Change
Change (Delete: TONER SAVE)
Change (Default value: AR-287/337/407)
Change (Default value: AR-287/337/407)
Change (Default value: AR-287/337/407)
Change (Delete: Fax item)
Add
Change (Add: ITALIAN/SWEDISH/DUTCH)
Add
Change
Add
Change
Add
Add (AR-507 Europe and U.K. only)
Change (Default value: AR-287/337/407)
Add
Refer to the
attached page
7-51 – 7-57.
[8]
DISASSEMBLY, ASSEMBLY, MAINTENANCE
No change
[9]
TROUBLE CODE LIST
Add (Trouble code: CE)
Refer to the
attached page
9-1
[10]
OPERATIONAL DESCRIPTION
No change
Transfer charger
current
Adjustment spec
AR-250/280
/281/285/286
/335/336
AR-405
AR-501
/505
TC drum current
(Front surface mode)
+13.5
+1.5
m
A
+15.0
+1.5
m
A
+18.0
+1.5
m
A
TC drum current
(Back surface mode)
+13.5
+1.5
m
A
+15.0
+1.5
m
A
+18.0
+1.5
m
A
Transfer charger
current
Adjustment spec
AR-287
/337
AR-407
AR-507
TC drum current
(Front surface mode)
+13.5 to
+15.0
m
A
+15.0 to
+16.5
m
A
+18.0 to
+19.5
m
A
TC drum current
(Back surface mode)
+13.5 to
+15.0
m
A
+15.0 to
+16.5
m
A
+18.0 to
+19.5
m
A
Adjustment range
AR-250/280
/281/285/286
/335/336
AR-405
AR-501
/505
Separation DC
component
voltage (Front
surface mode)
–140 
±
10V
–150 
±
10V –200 
±
10V
Separation DC
component
voltage (Back
surface mode)
–140 
±
10V
–150 
±
10V –200 
±
10V
Adjustment range
AR-287
/337
AR-407
AR-507
Separation DC
component
voltage (Front
surface mode)
–140 
±
10V
–150 
±
10V –200 
±
10V
Separation DC
component
voltage (Back
surface mode)
–140 
±
10V
–150 
±
10V –200 
±
10V
AR-287/337
AR-407/507
– 2 –
4/5/2000
Page of 26