AR-335 (serv.man15). AR280 285 335 Service Manual-Trouble Code List - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp AR-335 (serv.man15) Service Manual online

Trouble code
Description
Main
code
Sub
code
H4
00
HL1
01
HL2
Content Too cold fusing section
Detail
The temperature does not reach the
preset value within the specified time (3
min. in usual modes; 5 min. in curl
correction mode.) after the power relay is
turned on.
Cause
Thermister defective
Heater lamp defective
Control PWB defective
Thermostat defective
AC power supply defective
Interlock switch defective
Check
and
remedy
Check heater lamp for blinking with
SIM5-2.
If lamp blinks properly:
  Check thermister and its harness.
  Check thermister input circuit of control
PWB.
If lamp does not light:
  Check heater lamp for broken wire and
thermostat for operation.
  Check interlock switch.
  Check lamp control circuit of AC PWB
and control PWB.
Clear the trouble with SIM14.
H5
01
Content 3 continuous POD1 not-reaching JAM
detection
Detail
3 continuous POD1 not-reaching JAM
detection
Cause
Check that the fusing JAM is completely
cancelled. (Jam paper may be
remained.)
POD1 sensor trouble or improper
harness connection
Improper installation of the fusing
harness.
Check
and
remedy
Check JAM paper in the fusing section.
(Winding, etc.)
Check POD1 sensor harness. Check the
fusing unit installation.
Cancel the trouble with SIM 14.
L1
00
Content Scanner field trouble
Detail
Scanner field is not finished within the
specified time. (timer is change by
magnification)
Cause
Mirror unit defective
Scanner wire disconnected
Check
and
remedy
Check scanning operation with SIM1-1.
L3
00
Content Scanner return trouble
Detail
Scanner return is not finished within the
specified time. (timer is change by
magnification)
Cause
Mirror unit defective
Scanner wire disconnected
Check
and
remedy
Check scanning operation with SIM1-1.
Trouble code
Description
Main
code
Sub
code
L4
01
Content Main motor lock detected
Detail
Motor lock signal is detected for 1.5
seconds during main motor rotation
Cause
Main motor defective
Improper connection of harness between
PCU PWB and main motor
Control circuit defective
Check
and
remedy
Check main motor operation with
SIM25-1.
Check harness and connector between
PCU PWB and main motor.
L6
10
Content Polygon motor lock detected
Detail
It was judged that there is no output of
polygon motor lock signal of LSU.
The lock signal was checked at about
10-second intervals after the polygon
motor started rotating. As result, it was
judged that the polygon motor failed to
operate normally.
Cause
Disconnected connecter to LSU or
detached harness inside LSU or broken
wire.
Polygon motor defective
Check
and
remedy
Check polygon motor operation with
SIM61-1.
Check harness and connector for
connection. Replace LSU if needed.
L8
01
Content No full-wave signal
Detail
Full-wave signal is not detected.
Cause
PCU PWB trouble
Power unit trouble
Check
and
remedy
Check connection of the harness and the
connector.
Replace the PCU PWB. 
Replace the power unit.
02
Content Full-wave signal abnormality
Detai
Full-wave signal frequency abnormality
detected.
(The detected frequency: 69Hz or above
or 42.5Hz or below)
Cause
Check for disconnection or improper
connection of the connector of the PCU
PWB and the power PWB harness.
PCU PWB trouble
Power unit trouble
Check
and
remedy
Check connection of the harness and
connector.
Replace the power unit.
11 – 5
Page of 10
Display

Click on the first or last page to see other AR-335 (serv.man15) service manuals if exist.