AR-280 (serv.man15). AR280 285 335 Service Manual-Trouble Code List - Sharp Copying Equipment Service Manual (repair manual). Page 6

Read Sharp AR-280 (serv.man15) Service Manual online

Trouble code
Description
Main
code
Sub
code
F2
32
Content Process control trouble (drum marking
sensor defective)
Detail
Usually the sensor gain is adjusted so
that the output is a certain value, by
reading the drum base surface with the
drum marking sensor before starting
process control.
However, a certain output is not obtained
by adjusting the sensor gain.
Cause
Drum marking sensor defective
Improper connection of harness between
PCU PWB and drum marking sensor
Drum marking sensor contaminated
OPC drum cleaning improper
Charging voltage improper
Check
and
remedy
Check process control output with
SIM44-02. (Do not adjust.)
If the result is far different from the
specified value, it suggests the sensor is
defective. Check the sensor and
harness.
If the deviation is relatively small, check
the sensor and drum surface for
contamination.
37
Content Drum marking sensor gain adjustment
error
Detail
When the drum marking area surface is
scanned with the drum marking sensor
before starting process control and the
sensor gain ia adjusted until a constant
output is provided, the output is not be
constant though the sensor gain is
changed.
Cause
Drum marking sensor trouble
Improper connection between PCU PWB
and drum marking sensor
Drum marking sensor is dirty
OPC drum cleaning trouble
Check
and
remedy
Perform the gain adjustment of process
control sensor with SIM 44-2.
If ERROR is displayed, it may be a
breakdown. Check the sensor and the
harness.
When the adjustment is completed,
check the drum surface conditions.
F3
12
Content Upper cassette lift-up trouble
Detail
UPED does not turn on within the
specified time.
ULUD does not turn on within the
specified time.
Cause
UPED or ULUD defective
Upper cassette lift-up motor defective
Improper connection of harness between
PCU PWB, lift-up unit, and paper feed
unit.
Check
and
remedy
Check UPED, ULUD and their harness
and connector.
Check lift-up unit.
Trouble code
Description
Main
code
Sub
code
F3
22
Content Lower cassette lift-up trouble
Detail
LPED does not turn on within the
specified time.
LLUD does not turn on within the
specified time.
Cause
LPED or LLUD defective
Lower cassette lift-up motor defective
Improper connection of harness between
PCU PWB, lift-up unit, and paper feed
unit.
Check
and
remedy
Check LPED, LLUD, their harnesses and
connectors.
Check lift-up unit.
H2
00
HL1
01
HL2
Content Thermister open
Fusing unit not installed
Detail
Thermister is open (more than 4.6-V
input voltage is detected).
Fusing unit not installed
Cause
Thermister defective
Control PWB defective
Improper connection of fusing connector
AC power supply defective
Fusing unit not installed
Check
and
remedy
Check harness and connector between
thermister and control PWB.
Clear the display of self-diagnostics with
SIM14.
H3
00
HL1
01
HL2
Content Too hot fusing section
Detail
The fusing temperature is over 241.5° C
(less than 1.3-V input voltage is
detected.)
Cause
Thermister defective
Control PWB defective
Improper connection of fusing unit
connector
AC power supply defective
Check
and
remedy
Check heater lamp operation with
SIM5-2.
If lamp blinks properly:
  Check thermister and its harness.
 Check 
thermister 
input 
circuit 
of 
control
PWB.
If lamp lights and stays lit:
  Check lamp control circuits of AC PWB
and control PWB.
Clear the trouble with SIM14.
11 – 4
Page of 10