(2) Density adjustment procedure
a. Automatic adjustment for each density mode
1) Execute SIM 46-2 (2-value mode) and SIM 46-3 (HiFi mode).
2) Change the values to adjust.
3) Be careful that the following contents are automatically changed
when SIM 46-2 (2-value mode) is executed.
B: CH3.0 .....CH1.0 
 5.0
(SIM 46-9 set value)
C: MIX3.0....MIX1.0 
 5.0
(SIM 46-10 set value)
D: PH3.0 .....PH1.0 
 PH5.0
(SIM 46-11 set value)
Be careful that the following contents are automatically
changed when SIM 46-3 (HiFi mode) is executed.
B: CH3.0 .....CH1.0 
 5.0
(SIM 46-5 set value)
C: MIX3.0....MIX1.0 
 5.0
(SIM 46-6 set value)
D: PH3.0 .....PH1.0 
 PH5.0
(SIM 46-7 set value)
4) After changing the values, make a sample copy in each mode and
check the following specifications are satisfied.
Adjustment specifications
Mode
EXP
Chart
No.
Adjustment
level
Chart
No.
Adjustment
level
Character
3
3
Copied.
2
Not copied.
Character/
Photo
3
3
Copied.
2
Not copied.
Photo
3
3
Copied.
2
Not copied.
Auto
3
Copied.
2
Not copied.
When the sample copy is too light, make the values greater.
When the sample copy is too dark, make the values
smaller.
Adjustment range: 30 
 170
b. Individual adjustment in each mode
This adjustment is to set the values for each density level in each
mode. It is advisable to use the previous adjustment for each density
mode normally.
1) Execute SIM 46-5 (HiFi Text) or SIM 46-11 (2-value photo individ-
ual setting). (The adjustment procedure of SIM 46-5 and SIM
46-11 are the same.)
2) Change the value to adjust.
3) After changing the values, make a sample copy and check it.
E. Paper feed
(1) Manual paper feed size detection level adjustment
1) Execute SIM 40-2.
2) Extend the manual paper feed guide fully.
3) Press [MAX POSITION] on the LCD of the operation panel to
highlight it.
4) Press [EXECUTE] on the LCD of the operation panel to highlight
it.
If normal, the highlight is shifted from [MAX POSITION] to [MIN
POSITION].
5) Narrow the manual paper feed tray guide fully.
6) Press [EXECUTE] on the LCD of the operation panel to highlight
it.
Check that [COMPLETE] is highlighted.
7) Press the CA key to cancel the simulation.