Read Sharp AR-161 Handy Guide online
Fault Finding
Version 2.6
Issue 12/02
25
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
MODEL AR161 AR200 AR205
FAULT
FAULT
No dual copy
ADVICE Set the cassette to correct size A4.
MODEL AR161 AR200 AR205
FAULT
FAULT
L4-10.
ADVICE Error code not included in the manual. See T/B 031
MODEL AR161 AR200 AR205
FAULT
FAULT
White line on copies or drum wear.
ADVICE Replace developer seals (modified) also check drum earth.
Part No PSHEP0035YST.Z (X2). Note: Drum now improved.
MODEL AR161 AR200 AR205
FAULT L4-01
ADVICE Replace discharge plate. See technical bulletin 079.
FAULT L4-01
ADVICE Replace discharge plate. See technical bulletin 079.
.
MODEL
AR161 AR200 AR205
FAULT
L3-00.
ADVICE
Optics scan forward approx. half inch then enters L3-00.
Mirror base return trouble. Replace mirror home base sensor.
Mirror base return trouble. Replace mirror home base sensor.
MODEL AR161 AR200 AR205
FAULT Skewing from cassette.
ADVICE
FAULT Skewing from cassette.
ADVICE
Check right hand door. Check cassette "Lugs".
Ensure PF tyres are correctly aligned.
Ensure PF tyres are correctly aligned.
MODEL
AR161 AR200 AR205
FAULT
Heater lamp breaking during maintenance.
ADVICE
Read service manual section 11-3 for correct disassembly Instructions.
Remove pressure roller first.
Click on the first or last page to see other AR-161 service manuals if exist.