Read Sharp AR-161 Handy Guide online
Routine Maintenance
Version 2.6
Issue 12/02
11
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS SUPPORT
TECHNICAL SERVICES GROUP
Section
Adjustment Item
Adjustment
Procedure
Process
1 Developer doctor gap
2 MG roller main pole position
2 MG roller main pole position
Laser scanner
1 Horizontal image distortion
LSU lever adjustment
2 Print off centre
Sim 50-10
Scanner
1 Vertical image distortion
balance
Copy lamp unit
installing position
installing position
2 Vertical image distortion
balance
No2/3 mirror base
installing position
installing position
3 Vertical image distortion
Winding pulley
position
position
4 Horizontal image distortion
F rail height adjust
5 Main scan magnification
ratio
CCD unit position
6 Main scan magnification
ratio
Sim 48-1
7 Original off centre
Sim 50-10
OC Detection
1
1
Detection position adjust
207 – 302mm
Original sensor
1 Size sensor adjust
(
not AR161
)
Sim 41 - 3
Copy Density
1 Copy mode
Sim 46
Paper Trans
1 Resist Roller Buckle
Sim 51-2