AR-161 (serv.man49). Replacement procedure for the polygon motor in the LSU unit. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp AR-161 (serv.man49) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
DCE536
(3) Remove the four M3 x 8P screws to detach the
polygon motor.
Notes:
 
Prevent the optical axis from being
displaced, do not apply any load to the
LSU PWB.
 
When removing the M3 x 8P screws be
careful that the screwdriver does not
make contact with the lens.
(4) Lift the polygon motor and remove the connector to
detach the polygon motor.
Note: Disengage the 10 hooks of the LSU cover
one by one in the shown directiuon