AR-161 (serv.man10). AR161 Service Manual-Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-161 (serv.man10) Service Manual online

Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
20
1
Maintenance counter clear
Used to clear the maintenance counter. 
2
21
1
Maintenance cycle setting
Used to display the currently set maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is
pressed, the set value is stored. 
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 15000 sheets
3: 30000 sheets
4: 150000 sheets
5: FREE (999999 sheets)
2
Mini maintenance counter
display
Used to display the currently set mini maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is
pressed, the set value is stored. 
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 10000 sheets
3: FREE (999999 sheets)
22
1
Maintenance counter
display
Used to display the current maintenance counter value. 
1
2
Maintenance preset value
display
Used to display the current maintenance preset value (set with SIM
21-1). 
1
3
JAM memory display
Used to display a JAM generated during copying on the JAM position
display on the operation panel. Max. 30 recent jams are stored. 
Key operation
Display
JAM history select: 
    Magnification ratio key
The history number (1 ~ 30) is displayed
on the display.
The JAM position LED corresponding to
the history number is lighted. 
4
Total JAM counter display
Used to display the current total JAM counter value. 
1
5
Total counter display
Used to display the current total counter value. 
1
6
Developing counter
display
Used to display the current developing unit counter value. 
1
7
Developing preset counter
value display
Used to display the current mini maintenance preset value (set with SIM
21-2). 
1
8
SPF counter display
Used to display the current SPF counter value. 
1
9
Paper feed counter display
Used to display the current paper feed counter value for each paper feed
port. 
1
Key operation
Paper feed port selection: Tray select key
12
Drum counter display
Used to display the current drum counter value. 
1
14
Flash ROM version display
Used to display the version number of the flash ROM of each PWB.
15
Trouble memory display
Used to display the actually occurred trouble codes on the display on the
operation panel. When the start key is pressed during the main code
display, the sub code is displayed. Max. 20 recent trouble codes are
stored.
Key operation
Display
Sub code display: Start key
Hysteresis 1 
 10: The upper digit of 
  display 
"A" 
 "J" lights up.
Hysteresis 11 
 20: The upper digit of 
    display "A: 
 "J" blinks.
Trouble code history
select: Magnification ratio
display key
Display without trouble code
Main code: "----"
Sub code: "00"
1: Each counter display method
To display 12345: 123 (0.75 sec) 
 Blank (0.35sec) 
 456 (0.75 sec) 
 Blank (1.0 sec) 
 repetition
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35sec) 
 000 (0.75 sec) 
 Blank (1.05 sec) 
 Repetition
AR-160/160 FM/E [8] SIMULATION 12/1/1998
AR-161
8 – 5
Page of 13
Display

Click on the first or last page to see other AR-161 (serv.man10) service manuals if exist.