AR-151 (serv.man3). AR151 156-Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 107

Read Sharp AR-151 (serv.man3) Service Manual online

TABLE-5: Data which is sent in the Signal send mode
MODE #
MENU (DATA)
DISPLAY
1
00000000b
1:00000000b
2
11111111b
2:11111111b
3
01010101b
3:01010101b
(5) Image memory clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
 
)
3
Press 1, 0.
10:IMAGE MEM CLEAR
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
 
)
The image data are cleared and this mode is
terminated.
(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
 
)
3
Press 1, 4.
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4
Press 
 or 
.
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
Press 
 to decrease by 1%.
Press 
 to increase by 1%.
5
Press ENTER.
“1590” is dialed.
6
(Adjustment/test end)
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
(7) Dial test mode (Tone)
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
 
)
3
Press 1, 6.
16:DIAL TEST TONE
“123456789
0#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure
LCD
Operation
1
Press FUNCTION, 9, 
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
 
)
3
Press 2, 1.
21:PRINT SOFT SW
The soft switch list is printed.
This mode is terminated.
AR-F152
9 – 18
Page of 127